Related Experiment Video
Updated: Feb 15, 2026

09:23
Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators
Published on: May 30, 2014
15.1K
Efficient, 2-5 μm tunable CdSiP2 optical parametric oscillator pumped by a laser source at 1.57 μm
Optics Letters
|January 13, 2018
Abstract:
We report on first demonstrations of CdSiP2-based optical parametric oscillators that are pumped by eye-safe Q-switched nanosecond laser sources operating at 1.57 μm. One device reached 40% optical conversion efficiency generating 10 mJ of energy near degeneracy in the 3 μm region. Angle tuning of a similar device through the middle infrared was demonstrated with the signal and idler waves being tuned from 2.28 μm to 5.05 μm.
More Related Videos
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
4.9K
V-type pumps are ATP-driven pumps found in the vacuolar membranes of plants, yeast, endosomal and lysosomal membranes of animal cells, plasma membranes of a few specialized eukaryotic cells, and some prokaryotes. They are also known as the V1Vo-ATPase, that couple ATP hydrolysis to transport protons against a concentration gradient.
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
4.9K
Oscillations In An LC Circuit
3.2K
An idealized LC circuit of zero resistance can oscillate without any source of emf by shifting the energy stored in the circuit between the electric and magnetic fields. In such an LC circuit, if the capacitor contains a charge q before the switch is closed, then all the energy of the circuit is initially stored in the electric field of the capacitor. This energy is given by
3.2K
Forced Oscillations
8.0K
When an oscillator is forced with a periodic driving force, the motion may seem chaotic. The motions of such oscillators are known as transients. After the transients die out, the oscillator reaches a steady state, where the motion is periodic, and the displacement is determined.
8.0K
ATP Driven Pumps II: P-type Pumps
6.5K
The P-type pumps are a large family of integral membrane transporter ATPases. They are divided into five major types based on substrate specificity, from I to V.
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
6.5K
Damped Oscillations
7.4K
In the real world, oscillations seldom follow true simple harmonic motion. A system that continues its motion indefinitely without losing its amplitude is termed undamped. However, friction of some sort usually dampens the motion, so it fades away or needs more force to continue. For example, a guitar string stops oscillating a few seconds after being plucked. Similarly, one must continually push a swing to keep a child swinging on a playground.
Although friction and other non-conservative...
Although friction and other non-conservative...
7.4K
5-Number Summary
5.8K
In a dataset, the 5-number summary includes the minimum data value, the data value of the first quartile, the median data value or data value of the second quartile, the data value of the third quartile, and the maximum data value. These 5 data values can be visualized as a box and whisker plot.
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
5.8K

