Related Experiment Video
Updated: Feb 15, 2026

Paw-Dragging: a Novel, Sensitive Analysis of the Mouse Cylinder Test
Published on: April 29, 2015
Thermally sensitive scattering of terahertz waves by coated cylinders for tunable invisibility and masking
Abstract:
Temperature-sensitive scattering of terahertz (THz) waves by infinitely long, cylindrical core-shell structures was theoretically studied. Each structure is a dielectric cylinder coated with an InSb shell illuminated by either a transverse-electric (TE) or a transverse-magnetic (TM) plane wave. InSb is a thermally tunable semiconductor showing a transition from dielectric to plasmonic state at THz frequencies. Accordingly, the total scattering efficiency (TSE) can be thermally tuned for both polarization states of the incident plane wave. The spectral locations of the maxima and minima of the TSE of an InSb-coated cylinder can be exploited for cloaking the core. At least three scenarios lead to the strong suppression of scattering by a single core-shell structure in different spectral regimes when the temperature is fixed. The excitation of localized surface-plasmon resonances is the feature being common for two of them, while the effect of volumetric resonance dominates in the third scenario. Regimes that are either highly or weakly sensitive to the core material were identified. Weak sensitivity enables masking, i.e., the core material cannot be identified by a far-zone observer. The TSE minima are usually significantly sensitive to the polarization state, but ones with weak sensitivity to the polarization state also exist.
Related Concept Videos
The Wave Nature of Light
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Scatter Plot

