Related Experiment Video
Updated: Feb 15, 2026

A New Ex Vivo Model for the Evaluation of Endoscopic Submucosal Injection Material Performance
Published on: October 19, 2018
Development of a new ex vivo model for evaluation of endoscopic submucosal injection materials performance
Ryohei Hirose1, Takaaki Nakaya2, Yuji Naito3
1Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan; Department of Infectious Diseases, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Background And Aims:
Development of high-performance submucosal injection materials (SIMs) contribute to the advancement of endoscopic therapy for early-stage gastrointestinal neoplasms. This study aimed to develop a new ex vivo model that mimics the human gastrointestinal tract to evaluate the performance (the height and duration of the submucosal elevation) of various SIMs in detail.
Methods:
A new ex vivo model that applies a constant tension to the tested specimen (the porcine gastric specimen) was developed. SIMs were injected into the submucosa at the center or edge of the tested specimen, and submucosal elevation heights (SEHs) were measured over time.
Results:
The average value and standard deviation of SEH determined using the conventional model (the tested specimen was fixed with pins) were higher than those obtained using the new model, which showed that the new model could precisely measure the SEH of a given SIM. In addition, the performance (SEH) of SIMs decreased with increasing tension applied to the specimen, suggesting that the performance of SIMs deteriorates with the over-expansion of the gastrointestinal tract. The submucosal elevation formed at the specimen edge disappeared faster than that formed at the specimen's center.
Conclusions:
The proposed new ex vivo model allows accurate SEH measurement under uniform conditions and detailed comparison of the performances of various types of SIMs and can contribute to the development of high-performance materials.
Related Concept Videos
Drug Product Performance: In Vitro–In Vivo Correlation
Self-Evaluation Maintenance Model
Genetic Material
Members Made of Elastoplastic Material
As the bending moment...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...