Related Experiment Video
Updated: Feb 15, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A
Marc Balmer1, Benedikt C Spies2,3, Kirstin Vach4
1Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
Aim:
The aim of the present investigation was to evaluate clinically and radiographically the outcome of zirconia oral implants after 3 years in function.
Materials And Methods:
In 60 patients in need of either a single-tooth replacement or a three-unit fixed dental prosthesis (FDP), a total of 71 one-piece zirconia implants were placed and immediately restored with temporary fixed prostheses. After a period of at least 2 months in the mandible and at least 4 months in the maxilla, zirconia-based reconstructions were cemented. The implants were clinically and radiologically examined at implant insertion, prosthetic delivery, at 6 months and then yearly up to 3 years. A linear mixed model was used to analyze statistically the influence of prognostic factors on changes in the marginal bone level.
Results:
Seventy-one implants (48 in the mandible, 23 in the maxilla) inserted in 60 patients were restored with 49 crowns and 11 FDP. One patient lost his implant after 5 weeks. Five patients with one implant each could not be evaluated after 3 years. Based on 55 patients with a total of 66 implants, the mean survival rate was 98.5% after 3 years in function. A statistically significant mean marginal bone loss (0.70 mm ± 0.72 mm) has been detected from implant insertion to the 3-year follow-up. The largest marginal bone loss occurred between implantation and prosthetic delivery (0.67 mm ± 0.56 mm). After delivery, no statistically significant bone level change was observed (0.02 mm ± 0.59 mm). None of the investigated prognostic factors had a significant influence on changes in the marginal bone level.
Conclusions:
After 3 years in function, the investigated one-piece zirconia implant showed a high survival rate and a low marginal bone loss. The implant system was successful for single-tooth replacement and three-unit FDPs. Further investigations with long-term data are needed to confirm these findings.
Related Concept Videos
Measurement: Standard Units
Tooth Anatomy
The Crown, Neck, and Root
The visible part of the tooth is referred to as the crown. It's covered by enamel, the hardest substance in the human body. The crown is uniquely shaped for each type of tooth, allowing for different functions such as cutting, tearing, or...
Measurement: Derived Units
Fixing Double-strand Breaks
Fixed Action Patterns
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...

