Related Experiment Video
Updated: Feb 15, 2026

Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
LVIS Blue as a low porosity stent and coil adjuvant
Matthew J Koch1, Christopher J Stapleton1, Scott B Raymond2
1Department of Neurosurgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
Introduction:
The LVIS Blue is an FDA-approved stent with 28% metallic coverage that is indicated for use in conjunction with coil embolization for the treatment of intracranial aneurysms. Given a porosity similar to approved flow diverters and higher than currently available intracranial stents, we sought to evaluate the effectiveness of this device for the treatment of intracranial aneurysms.
Methods:
We performed an observational single-center study to evaluate initial occlusion and occlusion at 6-month follow-up for patients treated with the LVIS Blue in conjunction with coil embolization at our institution using the modified Raymond-Roy classification (mRRC), where mRRC 1 indicates complete embolization, mRRC 2 persistent opacification of the aneurysm neck, mRRC 3a filling of the aneurysm dome within coil interstices, and mRRC 3b filling of the aneurysm dome.
Results:
Sixteen aneurysms were treated with the LVIS Blue device in conjunction with coil embolization with 6-month angiographic follow-up. Aneurysms were treated throughout the intracranial circulation: five proximal internal carotid artery (ICA) (ophthalmic or communicating segments), two superior cerebellar artery, two ICA terminus, two anterior communicating artery, two distal middle cerebral artery, one posterior inferior cerebellar artery, and two basilar tip aneurysms. Post-procedurally, there was one mRRC 1 closure, five mRRC 2 closures, and 10 mRRC 3a or 3b occlusion. At follow-up, all the mRRC 1 and mRRC 3a closures, 85% of the mRRC 3b closures and 75% of the mRRC 2 closures were stable or improved to an mRRC 1 or 2 at follow-up.
Conclusions:
The LVIS Blue represents a safe option as a coil adjunct for endovascular embolization within both the proximal and distal anterior and posterior circulation.
More Related Videos
11:14Combining Wet and Dry Lab Techniques to Guide the Crystallization of Large Coiled-coil Containing Proteins
Published on: January 6, 2017
05:37Human Internal Mammary Artery IMA Transplantation and Stenting: A Human Model to Study the Development of In-Stent Restenosis
Published on: May 9, 2012
Related Concept Videos
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
Porosity in Cement Paste
The balance of water to cement in the mix is...
Chromatin Packaging
The chromatin
In combination with specialized DNA binding protein called Histones, the DNA double helix forms a compact DNA: protein complex called chromatin. The chromatin itself is further compacted into higher-order...
Protein-protein Interfaces
Globular and Fibrous Proteins
Globular proteins are also known as spheroproteins and typically are approximately round in shape. They contain a mix of amino acid types and contain differing sequences in their primary structures. Globular proteins have many different functions, such as enzymes, cellular messengers, and molecular transporters. These roles often require the proteins to be...
DNA Packaging