A sensitive SPR biosensor based on hollow gold nanospheres and improved sandwich assay with PDA-Ag@Fe3O4/rGO
Shuo Li1, Qiong Wu1, Pinyi Ma1
1College of Chemistry, Jilin University, Qianjin Street 2699, Changchun 130012, PR China.
Abstract:
A novel surface plasmon resonance (SPR) biosensor based on hollow gold nanospheres (HGNPs) and an improved sandwich assay was developed to detect rabbit IgG. The electromagnetic coupling between the HGNPs and Au film, and the notable plasmonic fields spread over the inner and outer surfaces of HGNPs, led to the considerable amplification of the SPR signal. Polydopamine-Ag@Fe3O4/reduced graphene oxide (PDA-Ag@Fe3O4/rGO) was introduced to bind detection antibody (Ab2) to form the improved sandwich structure. Ag nanoparticles were excited to produce SPR and their hot electrons were doped on graphene thin films, which amplified the response of biomolecules. Magnetic nanoparticles (Fe3O4) simplified the collection of Ab2-PDA-Ag@Fe3O4/rGO. An external layer of polydopamine (PDA) permitted the efficient immobilization of Ab2 without activation via abundant functional groups and protected the nanoparticles from etching or agglomeration. In addition, because of its large mass, Ab2-PDA-Ag@Fe3O4/rGO also played a key role in the further amplification of the SPR response signals. This novel SPR biosensor exhibited an effective response to the rabbit IgG at the different concentrations ranging from 0.019 to 40.00μgmL-1. This value is 132 times lower than that observed for a traditional SPR biosensor based on Au-3-mercaptopropionic acid and 8 times lower than that obtained from an Ab2 sandwich assay, which indicates that the SPR sensor has high sensitivity. In addition, the designed biosensor showed satisfactory recoveries to detect the rabbit IgG spiked in serum samples. Therefore, the novel SPR biosensor with high sensitivity and acceptable recovery has potential for practical applications.
Related Concept Videos
Thin-Walled Hollow Shafts
Improving Translational Accuracy
Improving Translational Accuracy
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Urine Studies II: Urine Culture and Sensitivity Test