Related Experiment Video
Updated: Feb 15, 2026

Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
Acidity of substituted cathinones studied by capillary electrophoresis using the standard and fast alternative
Michał Woźniakiewicz1, Paweł Mateusz Nowak1, Małgorzata Gołąb1
1Jagiellonian University in Kraków, Faculty of Chemistry, Department of Analytical Chemistry, Gronostajowa St. 2, 30-387 Kraków, Poland.
Abstract:
Cathinone derivatives are notorious but still weakly characterized molecules, known mainly as components of the designer and illicit drugs. The knowledge on their acidity is scarce and incomplete, therefore, we decided to determine the pKa values for six of them: 2-methylmethcathinone, 3-methylmethcathinone, 4-methylmethcathinone, α-pyrrolidinovalerophenone, methylenedioxypyrovalerone and ephedrone. For that purpose we employed capillary electrophoresis, which is known for its accurateness in comparison to other analytical techniques. We used and compared two methodologically different approaches. The standard method relied on measuring electrophoretic mobility across the broad pH range and fitting the sigmoidal function. The obtained pKa values were in the range 8.59-9.10, thus these molecules remain mostly protonated and positively ionized in the physiological conditions. The alternative two-values (TVM) and one-value methods (OVM), proposed by us previously, have been used herein for the first time to the cationic molecules. TVM enables estimation of pKa using only two electrophoretic mobility values, referring to the total and partial ionization. OVM requires only a single measurement because mobility of ion is predicted theoretically. Both TVM and OVM yielded only a small deviation of pKa from the standard approach, averagely 0.07-0.09pH unit. Two important issues have also been addressed: the potential of a maximally fast calculation method using no repetition at the given pH, and the accuracy of method with regard to pH attributed to partial ionization. As a whole, the analytical potential of the TVM/OVM approach seems to be huge and invaluable for fast pKa screening/estimation.
More Related Videos
14:53Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Sputum Studies I: Gram Stain, cytology, and Acid-fast smear and culture
Gram Stain
The Gram Stain is an integral part of sputum studies. It involves the staining of sputum, which permits...
Nucleophilic Acyl Substitution of Carboxylic Acid Derivatives
Polyprotic Acids
Calculating Standard Free Energy Changes