Fluorescent and colorimetric dual-mode aptasensor for thrombin detection based on target-induced conjunction of split
Wenna Duan1, Xiuzhong Wang1, Haixia Wang1
1College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao 266109, China.
Abstract:
Since the lack of detection diversity of the single-signal readout strategy, it is urgent to develop fast and multisignal assay strategies. A highly selective and sensitive assay method with colorimetric and fluorometric dual signals readouts is presented in this paper. It is based on the principle that the target induced conjunction of split aptamer fragments assembled on the surface of Au nanoparticles (AuNPs). In the presence of targets, the color of solution changed from wine red to blue and can be measured both visual inspection and spectrophotometry because of the aggregation of AuNPs. At the same time, the report probes which are original hybrid with the anchoring aptamer fragments on the AuNPs surface can be released and recovers the fluorescence. By use of this detection strategy, the limit of detection for thrombin (TMB), as a model of analyte, were 0.45 and 0.16nM, respectively. Furthermore, this protocol can discriminate TMB from other analogue with high selectivity and can be used to detect TMB in human serum samples. The results came from the two signals were well consistent with each other, which demonstrated that it has application potential for detection of TMB in complex matrix.
More Related Videos
Related Concept Videos
Habitat Fragmentation
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....