Implanted Closed-Loop Gastric Electrical Stimulation (CLGES) System with Sensor-Based Feedback Safely Limits Weight
S Morales-Conde1, I Alarcón Del Agua1, L Busetto2
1Innovation and Minimal Invasive Surgery Unit, Hospital Virgen del Rocio, Avda Manuel Siurot, S/N, 41010, Sevilla, Spain.
Background:
Weight regain following bariatric surgery is not uncommon. Safe, effective weight loss treatment up to 1 year has been reported with the closed-loop gastric electrical stimulation (CLGES) system. Continuous recording of eating and activity behavior by onboard sensors is one of the novel features of this closed-loop electrical stimulation therapy, and may provide improved long-term weight maintenance by enhancing aftercare.
Methods:
Four centers participating in a 12-month prospective multicenter randomized study monitored all implanted participants (n = 47) up to 24 months after laparoscopic implantation of a CLGES system. Weight loss, safety, quality of life (QOL), and cardiac risk factors were analyzed.
Results:
Weight regain was limited in the 35 (74%) participants remaining enrolled at 24 months. Mean percent total body weight loss (%TBWL) changed by only 1.5% between 12 and 24 months, reported at 14.8% (95% CI 12.3 to 17.3) and 13.3% (95% CI 10.7 to 15.8), respectively. The only serious device-/procedure-related adverse events were two elective system replacements due to lead failure in the first 12 months, while improvements in QOL and cardiovascular risk factors were stable thru 24 months.
Conclusion:
During the 24 month follow-up, CLGES was shown to limit weight regain with strong safety outcomes, including no serious adverse events in the second year. We hypothesize that CLGES and objective sensor-based behavior data combined to produce behavior change. The study supports CLGES as a safe obesity treatment with potential for long-term health benefits.
Trial Registration:
ClinicalTrials.gov identifier: NCT01448785.
More Related Videos
11:18Closed-loop Neuro-robotic Experiments to Test Computational Properties of Neuronal Networks
Published on: March 2, 2015
11:06A Human-machine-interface Integrating Low-cost Sensors with a Neuromuscular Electrical Stimulation System for Post-stroke Balance Rehabilitation
Published on: April 12, 2016
Related Concept Videos
Feedback Loops
Cell Signaling Feedback Loops
Negative feedback loops
Most signaling systems have negative feedback loops that can perform different functions such as output limiter, and adaptation.
Output limiter
Upon receiving an input signal, the cellular response rapidly increases until a threshold is reached. Beyond this threshold, a negative feedback loop...
Positive and Negative Feedback Loops
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Feedback Inhibition
Limiting Reactant