Vector analysis of astigmatic changes and optical quality outcomes after wavefront-guided laser in situ
Juan A Durán1, Elisa Gutiérrez1, Rebeca Atienza1
1From the Instituto Clínico-Quirúrgico Oftalmológico (Durán, Gutiérrez, Atienza), Bilbao, the Basque Country University (Durán), Leioa, Vizcaya, and the Department of Optics (Piñero), Pharmacology and Anatomy, University of Alicante, Alicante, Spain.
Purpose:
To assess the ocular optical quality results as well as the astigmatic changes after wavefront-guided laser in situ keratomileusis (LASIK) in eyes with myopic astigmatism.
Setting:
Instituto Clínico-Quirúrgico Oftalmológico, Bilbao, Vizcaya, Spain.
Design:
Prospective case series.
Methods:
Thirty-three eyes having wavefront-guided LASIK with the Star S4IR excimer laser combined with the iDesign system were enrolled in the study. Changes in visual acuity, refraction, higher-order aberrations, and ocular scattering index (OSI) were evaluated during a 3-month follow-up. The Alpins method was used to analyze the astigmatic changes.
Results:
A significant reduction was observed in refraction (P < .001), with significant improvement in uncorrected (UDVA) and corrected (CDVA) distance visual acuities (P < .001). All eyes had a spherical equivalent within ±0.50 diopter (D) and UDVA of 20/25 or better at 90 days after surgery. A total of 27.3% of eyes gained lines of CDVA. No significant changes were observed in primary coma and spherical aberration (P ≥ .551). Likewise, no significant changes were observed in OSI (P = .361), with a mean 90-day postoperative value of 0.66 ± 0.58 (SD). A significant change to negative values of the magnitude of error (P = .007) and a significant decrease in the correction index (P = .004) were observed during the follow-up, with mean 90-day postoperative values of -0.24 ± 0.28 D and 0.86 ± 0.17 D, respectively.
Conclusion:
Wavefront-guided LASIK using a high-resolution aberrometer provided safe and efficacious correction of myopic astigmatism, with preservation of the ocular optical quality.
Related Concept Videos
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance
Quality of Water