Reliability of pulse waveform separation analysis responses to an orthostatic challenge
Lee Stoner1, Keeron Stone2, Erik D Hanson3
1Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA. dr.l.stoner@gmail.com.
Abstract:
Cardiovascular autonomic nervous system function can be assessed using an orthostatic challenge to induce arterial wave reflection. While arterial reflection is typically estimated using a central augmentation index, a superior estimation can be obtained using pulse wave separation analysis to estimate the aortic backward pressure wave (Pb). However, to be of value in a clinical or research setting, an assessment tool must be precise (reliable). Therefore, this study sought to determine the measurement precision of Pb responses to a modified tilt-table test. Twenty healthy adults (26.4 year (SD 5.2), 24.7 kg/m2 (SD 3.8), 55% female) were tested in a fasted state on three different mornings separated by a maximum of seven days. Pressure waveforms were recorded on the left arm, and aortic waveforms were generated using a generalized transfer function. Subsequently, a physiologic flow waveform was assumed to separate the aortic pressure wave into its forward and timing-independent backward (Pb) components. The criterion intra-class correlation coefficient of ≥0.75 was exceeded at baseline (0.79), following a 5-min tilt (0.75), and following a 5-min recovery from tilt (0.75). The standard error of measurement was 7%. These findings indicate that in a healthy cohort, the Pb response to an orthostatic challenge can be assessed with acceptable precision. The next step is to determine the sensitivity (validity) of this technique in identifying cardiovascular autonomic dysfunction in patient groups.
Related Concept Videos
Reliability and Validity
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Distribution Reliability and Automation
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences