Related Experiment Video
Updated: Feb 15, 2026

Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead
Mattia Liccardo1, Pasquale Nocerino2, Salzano Gaia3
1Ospedale San Giuliano, Via Giambattista Basile, 25, 80014, Giugliano in Campania, NA, Italy.
Purpose:
Subclavian access is a reliable technique for lead insertion in pacemaker and defibrillator (ICD) implantation, but it is often accompanied by complications. The aim of this study was to compare the efficacy of the ultrasound-guided axillary approach to the subclavian method.
Methods:
This randomized comparative study was performed on 174 patients: as a first attempt, 116 patients underwent the ultrasound-guided axillary access and 58 patients underwent the subclavian approach. A total of 364 leads were placed. Operators were trained in ultrasound-guided vein access technique.
Results:
Axillary access was successful in 69% of patients (32/46), in the training phase and, as a first attempt, in 91.4% of patients (106/116), in the randomized phase. When axillary approach failed, we performed the following: subclavian access in 5.2% of patients (6/116), cephalic approach in 2.6% of patients (3/116), surgical method in 0.9% of patients (1/116). The subclavian technique was effective, as a first attempt, in 55 patients (94.8%). When the subclavian access failed, the ultrasound axillary approach successfully performed in all three cases. During a mean follow-up of 18 ± 6 months, the number of lead complications was similar in the subclavian group compared to the axillary group (p = 0.664).
Conclusions:
As first attempt, ultrasound-guided axillary method showed similarly high-success rate than subclavian approach and well performed when the first attempt in subclavian group failed. Axillary access can be considered a safe and effective alternative technique to the conventional subclavian method for device implantation.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Self-Efficacy
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...