Related Experiment Video
Updated: Feb 15, 2026

Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
Published on: May 20, 2016
Numerical simulation of two consecutive nasal respiratory cycles: toward a better understanding of nasal physiology
Ludovic de Gabory1,2,3, Nicolas Reville1,3, Yannick Baux4
1Ear, Nose, and Throat (ENT) Department, University Hospital of Bordeaux, Hôpital Pellegrin, Bordeaux, France.
Background:
Computational fluid dynamic (CFD) simulations have greatly improved the understanding of nasal physiology. We postulate that simulating the entire and repeated respiratory nasal cycles, within the whole sinonasal cavities, is mandatory to gather more accurate observations and better understand airflow patterns.
Methods:
A 3-dimensional (3D) sinonasal model was constructed from a healthy adult computed tomography (CT) scan which discretized in 6.6 million cells (mean volume, 0.008 mm3 ). CFD simulations were performed with ANSYS©FluentTMv16.0.0 software with transient and turbulent airflow (k-ω model). Two respiratory cycles (8 seconds) were simulated to assess pressure, velocity, wall shear stress, and particle residence time.
Results:
The pressure gradients within the sinus cavities varied according to their place of connection to the main passage. Alternations in pressure gradients induced a slight pumping phenomenon close to the ostia but no movement of air was observed within the sinus cavities. Strong movements were observed within the inferior meatus during expiration contrary to the inspiration, as in the olfactory cleft at the same time. Particle residence time was longer during expiration than inspiration due to nasal valve resistance, as if the expiratory phase was preparing the next inspiratory phase. Throughout expiration, some particles remained in contact with the lower turbinates. The posterior part of the olfactory cleft was gradually filled with particles that did not leave the nose at the next respiratory cycle. This pattern increased as the respiratory cycle was repeated.
Conclusion:
CFD is more efficient and reliable when the entire respiratory cycle is simulated and repeated to avoid losing information.
Related Concept Videos
Nose and Nasal Cavity
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Physiology of Respiration I: Functions of the Respiratory System
Fundamental Processes in Respiration:
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Numerical Calculations
The solution to a problem is obtained using different methods. While manually solving algebraic symbols is one of the most common methods, the graphical method is often preferred. Computers...