Inclinometer Assembly Error Calibration and Horizontal Image Correction in Photoelectric Measurement Systems
Xiaofang Kong1, Qian Chen2, Jiajie Wang3
1Jiangsu Key Laboratory of Spectral Imaging and Intelligent Sense, School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China. xiaofangkong@163.com.
Abstract:
Inclinometer assembly error is one of the key factors affecting the measurement accuracy of photoelectric measurement systems. In order to solve the problem of the lack of complete attitude information in the measurement system, this paper proposes a new inclinometer assembly error calibration and horizontal image correction method utilizing plumb lines in the scenario. Based on the principle that the plumb line in the scenario should be a vertical line on the image plane when the camera is placed horizontally in the photoelectric system, the direction cosine matrix between the geodetic coordinate system and the inclinometer coordinate system is calculated firstly by three-dimensional coordinate transformation. Then, the homography matrix required for horizontal image correction is obtained, along with the constraint equation satisfying the inclinometer-camera system requirements. Finally, the assembly error of the inclinometer is calibrated by the optimization function. Experimental results show that the inclinometer assembly error can be calibrated only by using the inclination angle information in conjunction with plumb lines in the scenario. Perturbation simulation and practical experiments using MATLAB indicate the feasibility of the proposed method. The inclined image can be horizontally corrected by the homography matrix obtained during the calculation of the inclinometer assembly error, as well.
Related Concept Videos
Photoelectric Effect
NMR Spectrometers: Resolution and Error Correction
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Distance Corrections
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...