Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
Published on: December 23, 2022
A word of caution: never use tacks for mesh fixation to the diaphragm!
F Köckerling1, C Schug-Pass2, R Bittner3
1Department of Surgery and Center for Minimally Invasive Surgery, Academic Teaching Hospital of Charité Medical School, Vivantes Hospital, Neue Bergstrasse 6, 13585, Berlin, Germany. ferdinand.koeckerling@vivantes.de.
Background:
The mesh fixation technique used in repair of hiatal hernias and subxiphoid ventral and incisional hernias must meet strenuous requirements. In the literature, there are reports of life-threatening complications with cardiac tamponade and a high mortality rate on using tacks. The continuing practice of tack deployment for mesh fixation to the diaphragm and esophageal hiatus should be critically reviewed.
Methods:
In a systematic search of the available literature in May 2017, 23 cases of severe penetrating cardiac complications were identified. The authors became aware of two other cases in which they acted as medical experts. Furthermore, the instructions for use issued by the manufacturers of the tacks were reviewed with regard to their deployment in the diaphragm.
Results:
Twenty-three of 25 cases (92%) with severe cardiac injuries and subsequent cardiac tamponade were triggered by the use of tacks in the diaphragm. In six cases (24%), these related to ventral and incisional hernias with extension to the subxiphoid area, and in 19 cases (76%) to mesh-augmented hiatoplasty. Twelve of 25 (48%) patients died as a result of pericardial and/or heart muscle injury with cardiac tamponade despite heart surgery intervention. In the tack manufacturers' instructions for use, their deployment in the diaphragm, in particular in the vicinity of the heart, is contraindicated. Likewise, the existing guidelines urgently advise against the use of tacks in the diaphragm, recommending instead alternative fixation techniques.
Conclusions:
Tacks should not be used for mesh fixation in the diaphragm above the costal arch.
More Related Videos
Related Concept Videos
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Carbon-dioxide Fixation
Framing Effects