Related Experiment Video
Updated: Feb 15, 2026

Fluorescence Angiography for Evaluation of Aneurysm Perfusion and Parent Artery Patency in Rat and Rabbit Aneurysm Models
Published on: July 24, 2019
Comparative analysis of aneurysm volume by different methods based on angiography and computed tomography angiography
Víctor Hugo Escobar-de la Garma1, Marco Zenteno2, Felipe Padilla-Vázquez2
1Neuroendovascular Therapy Department, Instituto Nacional de Neurología y Neurocirugía, Manuel Velasco Suarez, Avenida Insurgentes Sur 3877, La Fama, CP, 14269, Mexico City, Mexico. victorhe.delagarma@gmail.com.
Abstract:
Endovascular treatment and prognosis of intracranial aneurysms are based on size and volume, which demand more accurate neuroimaging techniques. Aneurysm volume calculation is important to choose endovascular treatment modalities and packing density calculation. Of all these methods, it remains unknown which one is the most accurate to calculate aneurysm volume. The objective of this study is to compare the accuracy of three angiography-based versus three tomographic-based methods which calculate aneurysm volume. A retrospective study which included patients with ruptured and unruptured cerebral aneurysms diagnosed by angiogram and computed tomography angiography (CTA) was done. The accuracy of each method was assessed with an ellipsoid glass model of known volume, which helped us to adjust variation in volumetric measurements done with AngioSuite© and AngioCalc© softwares (based on angiographic and tomographic images), 3D-rotational angiography and 3D-CTA (tridimensional computed tomography angiography), based on measurements of diameters such as maximal width and maximal height. Descriptive statistics, ANOVA for repetitive samples and t test were used. We included 89 patients (126 saccular intracraneal aneurysms). AngioSuite© software (angiography-based) showed more accuracy compared to other methods in our control model. The geometric system (AngioCalc) based on CTA images was statistically different from all other methods studied. AngioCalc (CTA-based) demonstrated a significant difference compared with other methods hence, it may overestimate volume measurements. AngioSuite
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
09:23Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Comparing the Survival Analysis of Two or More Groups
Area Computation by the Alternative Coordinate Method
Aneurysm I: Introduction
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...