Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Restorative Care01:19

Restorative Care

2.4K
Restorative care is provided once a patient has been discharged from a healthcare facility and requires additional services. The additional services include home care, rehabilitation programs, and extended care. Restorative care centers help the patient regain their previous level of functioning or acquire a new level of functioning due to the incapacitating effects of a disease or a disability. It aims to assist patients in enhancing their quality of life by encouraging independence,...
2.4K
Automatic Processing and Automatic Social Behavior01:28

Automatic Processing and Automatic Social Behavior

270
Automatic processing refers to the cognitive operations that occur without conscious intent or awareness, playing a fundamental role in shaping social cognition and behavior. These processes enable individuals to navigate complex social environments efficiently by relying on mental shortcuts and pre-existing knowledge structures known as schemas. One of the most influential mechanisms underlying automatic processing is priming, which subtly activates mental representations through exposure to...
270
Passive Filters01:27

Passive Filters

1.0K
Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
1.0K
Active Filters01:25

Active Filters

1.4K
Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.4K
Accelerators01:17

Accelerators

294
Accelerators in concrete serve as admixtures to speed up the hardening process, enabling the concrete to achieve early strength faster. Although accelerators do not necessarily impact the time it takes concrete to set, they reduce this time in practice. A common accelerator is calcium chloride, which is particularly useful for hastening early strength development in cold weather or for rapid repair jobs that require quick heat generation after mixing.
The effectiveness of calcium chloride can...
294
Brain Imaging01:14

Brain Imaging

763
Brain imaging technologies provide critical insights into both the structure and function of the human brain, enabling medical professionals and researchers to diagnose, study, and treat neurological disorders or psychiatric disorders more effectively.
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans),  magnetic resonance imaging (MRI),  functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
763

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

MIS12 Is Required for Kinetochore-Microtubule Attachment in Oocyte Meiosis.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Recurrence Patterns and Prognostic Factors in Sentinel Lymph Node-Negative Melanoma in a Taiwanese Cohort With Predominant Acral Melanoma.

The Journal of dermatology·2026
Same author

Machine learning-based skin nerve morphometry for diabetic neuropathy: diagnostic and clinical implications.

Brain communications·2026
Same author

Clinical and Histopathological Prognostic Factors for Disease-Free Survival in Early-Stage Acral and Non-Acral Cutaneous Melanoma: A Retrospective Asian Cohort Analysis.

Cancer management and research·2026
Same author

Classification of lung nodules in CT images based upon a multiplane dense inception network.

Medical physics·2026
Same author

The curative effect of traditional Chinese medicine fumigation combined with acupotomy in the treatment of heel pain: A meta-analysis.

Medicine·2025
Same journal

SleepConFormer: A Single-Channel EEG Framework for Sleep Staging and Consciousness Assessment in Patients with Disorders of Consciousness.

IEEE transactions on bio-medical engineering·2026
Same journal

Modeling Partial and Total Support of Left Ventricular Assist Device for Discrete Hemodynamic Control Framework.

IEEE transactions on bio-medical engineering·2026
Same journal

A Low-Cost Wearable TI-TACS Stimulator With Bipolar Quadratic-Boost Converter for Current Stimulation Validation in the Rat Brain.

IEEE transactions on bio-medical engineering·2026
Same journal

EMG-Based Gait Estimation Using Koopman-Inspired Method.

IEEE transactions on bio-medical engineering·2026
Same journal

Soft Everting Robots for Medical Applications: A Review.

IEEE transactions on bio-medical engineering·2026
Same journal

Arterial spin labeling cerebral blood flow quantification from quantitative transport mapping based on multiscale fluid mechanics simulation and deep learning.

IEEE transactions on bio-medical engineering·2026
See all related articles

Related Experiment Video

Updated: Feb 15, 2026

Induction of Diffuse Axonal Brain Injury in Rats Based on Rotational Acceleration
06:14

Induction of Diffuse Axonal Brain Injury in Rats Based on Rotational Acceleration

Published on: May 9, 2020

9.0K

Brain MR Image Restoration Using an Automatic Trilateral Filter With GPU-Based Acceleration.

Herng-Hua Chang, Cheng-Yuan Li, Audrey Haihong Gallogly

    IEEE Transactions on Bio-Medical Engineering
    |January 19, 2018
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces a fast, automated method to remove noise from brain MRI scans. By using a new filter that adapts to image details and leveraging powerful graphics hardware, the system cleans images quickly and accurately without manual input.

    Keywords:
    image restorationmachine learningparallel computingnoise reduction

    Frequently Asked Questions

    More Related Videos

    Optical Scatter Microscopy Based on Two-Dimensional Gabor Filters
    14:58

    Optical Scatter Microscopy Based on Two-Dimensional Gabor Filters

    Published on: June 2, 2010

    10.0K
    Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
    14:08

    Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images

    Published on: April 13, 2013

    43.6K

    Related Experiment Videos

    Last Updated: Feb 15, 2026

    Induction of Diffuse Axonal Brain Injury in Rats Based on Rotational Acceleration
    06:14

    Induction of Diffuse Axonal Brain Injury in Rats Based on Rotational Acceleration

    Published on: May 9, 2020

    9.0K
    Optical Scatter Microscopy Based on Two-Dimensional Gabor Filters
    14:58

    Optical Scatter Microscopy Based on Two-Dimensional Gabor Filters

    Published on: June 2, 2010

    10.0K
    Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
    14:08

    Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images

    Published on: April 13, 2013

    43.6K

    Area of Science:

    • Medical imaging informatics within trilateral filter research
    • Computational neuroscience and diagnostic radiology

    Background:

    Noise reduction remains a persistent hurdle in clinical brain magnetic resonance imaging. Standard processing techniques often struggle to balance detail preservation with effective artifact removal. Prior research has shown that conventional smoothing approaches frequently blur critical anatomical boundaries. That uncertainty drove the need for more sophisticated, adaptive filtering frameworks. No prior work had resolved the trade-off between computational speed and restoration quality for large volumetric datasets. Existing methods often require significant manual parameter tuning, which limits their utility in high-throughput clinical environments. This gap motivated the development of a self-regulating solution capable of handling complex intensity variations. The current investigation addresses these limitations by integrating advanced texture analysis with high-performance hardware acceleration.

    Purpose Of The Study:

    The aim of this study is to develop a robust trilateral filter for efficient brain magnetic resonance image restoration. Researchers seek to address the persistent challenge of noise reduction in high-resolution medical scans. The project focuses on creating an algorithm that adapts to specific intensity variations within brain tissues. A primary goal involves automating the filtration process to eliminate the need for manual parameter adjustments. The team explores the use of machine learning to predict optimal settings based on image texture analysis. Another objective is to minimize computational time through the application of parallel processing hardware. The study investigates memory allocation and thread distribution to maximize the efficiency of the graphics processing unit. This work intends to provide a scalable solution for clinical applications requiring both speed and high-quality image output.

    Main Methods:

    Review Approach: The study employs a computational design to develop and validate a novel image restoration framework. Investigators extend existing bilateral filtering concepts by adding an intensity-based similarity function. They implement an entropy-driven mechanism to manage component weighting dynamically. To facilitate rapid execution, the team utilizes graphics processing unit parallelization strategies. The researchers focus on optimizing memory management and thread distribution for volumetric data processing. Automation is achieved by extracting texture features through a machine learning pipeline. A sequential forward floating selection technique identifies the most informative features from a large candidate set. Finally, a two-stage classification model predicts optimal settings for the filtering process.

    Main Results:

    Key Findings From the Literature: The proposed system achieved a speedup gain of 757 when processing large volumetric datasets. The entire image volume of 256 × 256 × 256 pixels was restored in under 0.5 seconds. Quantitative assessments revealed an ensemble average relative error of 0.53 ± 0.85% for the peak signal-to-noise ratio. The automated restoration process demonstrated high precision across all tested samples. The self-regulating filter outperformed various state-of-the-art noise reduction techniques in qualitative comparisons. These results confirm that the integration of machine learning provides reliable parameter estimation. The hardware-accelerated approach successfully handled the computational demands of high-resolution brain scans. The findings show that the algorithm maintains structural detail while effectively suppressing artifacts.

    Conclusions:

    The authors propose that this self-regulating algorithm offers a robust solution for rapid brain image restoration. Synthesis and implications suggest that the integration of parallel computing significantly reduces processing latency for large volumes. The researchers demonstrate that their automated parameter prediction achieves high accuracy compared to existing benchmarks. This work indicates that machine learning can effectively replace manual tuning in standard clinical workflows. The findings imply that the trilateral approach provides superior noise suppression while maintaining essential structural integrity. The study highlights the potential for deploying such tools in time-sensitive diagnostic environments. The evidence supports the utility of combining texture feature analysis with hardware-based speedups. Future clinical adoption may benefit from the observed efficiency gains in handling complex volumetric data.

    The researchers propose a trilateral filter that incorporates an intensity similarity function and an entropy-based regulator. This mechanism specifically targets the unique noise characteristics found in brain scans, allowing the system to adjust weighting components dynamically based on local intensity variations.

    The team utilizes a two-stage classifier combining support vector machines and artificial neural networks. This architecture predicts optimal filter parameters by analyzing texture features, which were selected from 98 candidates using a sequential forward floating selection scheme.

    Parallel computing on graphics processing units is necessary to manage the high computational load of volumetric data. The authors emphasize that memory allocation and thread distribution strategies are required to achieve the reported speedup gain of 757.

    The sequential forward floating selection scheme acts as a feature reduction tool. It identifies the most relevant texture information from the initial candidate pool, ensuring that the classifier receives high-quality input for accurate parameter prediction.

    The performance is measured using the peak signal-to-noise ratio. The researchers report an ensemble average relative error of 0.53 ± 0.85%, indicating that their automated approach maintains high precision during the restoration process.

    The authors suggest that this algorithm holds potential for clinical applications requiring rapid processing. They propose that the combination of speed and automation makes the tool suitable for environments where quick diagnostic turnaround is necessary.