Related Experiment Video
Updated: Feb 15, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Safety profile of near-zero fluoroscopy atrial fibrillation ablation with non-fluoroscopic catheter visualization:
Philipp Sommer1,2, Livio Bertagnolli1, Simon Kircher1
1Department of Electrophysiology, Heart Center, University of Leipzig, Struempellstr. 39, Leipzig, Germany.
Aims:
Efforts to reduce radiation exposure during catheter ablation procedures have included the use of various technological measures. Significant results have been achieved to the point where near lead-free procedures in routine clinical practice has become a realistic goal. The integration of MediGuide technology [non-fluoroscopic catheter visualization technology (NFCV)] and three-dimensional electroanatomical mapping is one of the methods developed in response to radiation reduction initiatives. We aimed to evaluate the impact of this NFCV technology on atrial fibrillation (AF) catheter ablation in terms of reduction in procedural and radiation time as well as safety aspects.
Methods And Results:
Between March 2012 and March 2017, a total of 1000 patients underwent AF ablation using NFCV. Patient and procedural data and complications within the first 3 months were entered into a prospective registry and analysed. We assessed procedure time, fluoroscopy time, and dose and complications. In a cohort of 1000 patients (62.9 ± 11 years; 72% men; left ventricular ejection fraction 57%; and left atrial diameter 43.2 mm), the median procedure time was 120 min, median fluoroscopy time was 0.90 min, and the median fluoroscopy dose of was 345.1 cGy · cm2. Stratification of the first (Group 1) and the last 250 (Group 2) cases showed significant improvement in the median procedure time (140-110 min) and reduction in the median fluoroscopy time (6-0.5 min) and the median dose (2263-151.9 cGy · cm2). The overall complication rate was 2.0%.
Conclusion:
The use of NFCV technology enables safe, consistent, and 'near lead-free' performance of AF ablation in routine clinical practice.
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Survey Safety
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Household Wiring And Electrical Safety
What is an Experiment?