Observation of a strong-coupling effect on electron-ion collisions in ultracold plasmas

Wei-Ting Chen1, Craig Witte1, Jacob L Roberts1

  • 1Department of Physics, Colorado State University, Fort Collins, Colorado 80523, USA.

Physical Review. E
|January 20, 2018
PubMed

Related Concept Videos

Titration Calculations: Strong Acid - Strong Base02:28

Titration Calculations: Strong Acid - Strong Base

Calculating pH for Titration Solutions: Strong Acid/Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
34.2K
Strong Acid and Base Solutions03:22

Strong Acid and Base Solutions

A strong acid is a compound that dissociates completely in an aqueous solution and produces a concentration of hydronium ions equal to the initial concentration of acid. For example, 0.20 M hydrobromic acid will dissociate completely in water and produces 0.20 M of hydronium ions and 0.20 M of bromide ions.
36.3K
Types Of Collisions - I01:04

Types Of Collisions - I

When two objects come in direct contact with each other, it is called a collision. During a collision, two or more objects exert forces on each other in a relatively short amount of time. A collision can be categorized as either an elastic or inelastic collision. If two or more objects approach each other, collide and then bounce off, moving away from each other with the same relative speed at which they approached each other, the total kinetic energy of the system is said to be conserved. This...
9.5K
Types of Collisions - II01:19

Types of Collisions - II

When two or more objects collide with each other, they can stick together to form one single composite object (after collision). The total mass of the object after the collision is the sum of the masses of the original objects, and it moves with a velocity dictated by the conservation of momentum. Although the system's total momentum remains constant, the kinetic energy decreases, and thus such a collision is an inelastic collision. Most of the collisions between objects in daily life are...
10.1K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.5K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
1.9K