Related Experiment Video
Updated: Feb 15, 2026

08:43
Calibration Procedures for Orthogonal Superposition Rheology
Published on: November 18, 2020
2.4K
IFCC Working Group Recommendations for Assessing Commutability Part 3: Using the Calibration Effectiveness of a
Jeffrey R Budd1, Cas Weykamp2, Robert Rej3
1Beckman Coulter, Chaska, MN.
Clinical Chemistry
|January 20, 2018
Summary
This study presents a method to assess reference material (RM) commutability for calibrators. Demonstrating RM effectiveness in producing equivalent clinical sample results across measurement procedures confirms its suitability for intended use.
Area of Science:
- Clinical Chemistry
- Laboratory Medicine
- Measurement Science
Background:
- Reference materials (RMs) are crucial for accurate laboratory testing.
- Ensuring commutability of RMs across different measurement procedures (MPs) is essential for reliable clinical sample (CS) results.
- Systematic errors in calibration models can arise from calibration fit, calibrator trueness, and commutability.
Purpose of the Study:
- To describe and illustrate a process for assessing the commutability of a reference material (RM) intended for use as a calibrator.
- To evaluate the RM's ability to yield equivalent clinical sample (CS) results across multiple measurement procedures (MPs).
- To confirm the RM's fitness for purpose in a calibration traceability scheme.
Main Methods:
- A process was developed to assess RM commutability by evaluating its performance in a calibration traceability scheme.
- Systematic errors (calibration fit, calibrator level trueness, commutability) were elucidated.
- An example using 40 CS results from 7 MPs demonstrated bias and variability estimation, followed by RM-based recalibration.
Main Results:
- Recalibration with the candidate RM reduced systematic error among MPs, confirming commutability when CS results achieved acceptable equivalence.
- The RM was deemed noncommutable for MPs where post-recalibration CS results did not agree with other MPs.
- Lack of agreement necessitated investigation into other causes, such as poor calibration fit, before concluding non-commutability.
Conclusions:
- The described process effectively assesses RM commutability for calibrator use.
- Commutability is demonstrated when an RM enables equivalent CS results across MPs after recalibration.
- The RM is considered fit for purpose for specific MPs where commutability is confirmed.
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
1.4K
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
1.4K
Glassware Calibration
1.5K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.5K
Instrument Calibration
805
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
805
Inertial Frames of Reference
9.0K
Newton’s first law is usually considered to be a statement about reference frames. It provides a method for identifying a special type of reference frame: the inertial reference frame. In principle, we can make the net force on a body zero. If its velocity relative to a given frame is constant, then that frame is said to be inertial. So, by definition, an inertial reference frame is a reference frame where Newton's first law holds valid. Newton's first law applies to objects with...
9.0K
Non-inertial Frames of Reference
7.3K
A reference frame accelerating or decelerating relative to an inertial frame is a non-inertial frame. To help understand this, consider what taking off in an airplane, turning a corner in a car, riding a merry-go-round, and the circular motion of a tropical cyclone all have in common. All these systems are accelerating, decelerating, or rotating relative to the Earth; hence, they all are non-inertial frames. All these systems exhibit inertial forces, which merely seem to arise from motion,...
7.3K
Framing Effects
8.0K
Information is everywhere and its presentation—such as how and when items are presented—can impact our perceptions and decisions surrounding the info. This broad concept umbrellas framing effects—influences that occur due to the way information is framed in its appearance, whether it’s purely the order or the specific wording of a message. Let’s take a look at numerous ways in which two versions of something can objectively say the same thing, yet we respond in...
8.0K

