High-throughput analysis using non-depletive SPME: challenges and applications to the determination of free and total concentrations in small sample volumes
Related Experiment Video
Updated: Feb 15, 2026

Determination of Total Lipid and Lipid Classes in Marine Samples
Published on: December 11, 2021
Ezel Boyacı1,2, Barbara Bojko1,3, Nathaly Reyes-Garcés1
1Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.
Abstract:
In vitro high-throughput non-depletive quantitation of chemicals in biofluids is of growing interest in many areas. Some of the challenges facing researchers include the limited volume of biofluids, rapid and high-throughput sampling requirements, and the lack of reliable methods. Coupled to the above, growing interest in the monitoring of kinetics and dynamics of miniaturized biosystems has spurred the demand for development of novel and revolutionary methodologies for analysis of biofluids. The applicability of solid-phase microextraction (SPME) is investigated as a potential technology to fulfill the aforementioned requirements. As analytes with sufficient diversity in their physicochemical features, nicotine, N,N-Diethyl-meta-toluamide, and diclofenac were selected as test compounds for the study. The objective was to develop methodologies that would allow repeated non-depletive sampling from 96-well plates, using 100 µL of sample. Initially, thin film-SPME was investigated. Results revealed substantial depletion and consequent disruption in the system. Therefore, new ultra-thin coated fibers were developed. The applicability of this device to the described sampling scenario was tested by determining the protein binding of the analytes. Results showed good agreement with rapid equilibrium dialysis. The presented method allows high-throughput analysis using small volumes, enabling fast reliable free and total concentration determinations without disruption of system equilibrium.
Related Concept Videos
Concentration Cells
Consider the following voltaic cell:
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Solution Concentration and Dilution
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Constant Volume Calorimetry