Related Experiment Video
Updated: Feb 15, 2026

Author Spotlight: Advantages of Pressure-Volume Loop Measurement Method in Cardiovascular Research
Published on: January 12, 2024
Transorbital Doppler with carotid siphon monitoring detects right-to-left shunt effectively
Zhihui Duan1,2, Zhiyuan Yang2, Binbin Song2
1a Department of Neurology , The 2ndAffiliated Hospital of Zhengzhou University , Zhengzhou , P.R.China.
Abstract:
Background Transtemporal Doppler (TTD) with middle cerebral artery (MCA) is widely used for right-to-left shunt (RLS) detection. However, an alternative method for patients without suitable temporal bone windows should be established. The present study prospectively evaluated the effectiveness of transorbital Doppler (TOD) with carotid siphon (CS) monitoring in detecting RLS. Methods A total of 357 subjects with sufficient temporal bone windows underwent simultaneous TTD with MCA and TOD with CS. After injection of microbubbles, the numbers of artificial high-intensity signals were recorded at rest and after Valsalva maneuver. Results TOD with CS detected RLS in 146 patients. Sensitivity was 97.1%, specificity 95%, positive predictive value 92.5%, and negative predictive value 98.1%. The total positive rates for RLS detection by CS (40.9%) and MCA (37.8%) monitoring were comparable without significant difference, but TOD with CS detected significantly more grade 2 and 3 RLS than TTD with MCA (p = 0.001). The RLS rates of cryptogenic stroke patients was significantly higher than that of healthy controls, and RLS in cryptogenic stroke was remarkably higher than that in transient ischemia attack patients (p < 0.05). TOD with CS examined significantly more grade 2 and 3 RLSs than the MCA approach in the cryptogenic stroke patients (p = 0.037). Conclusion TOD with CS monitoring is able to detect RLS effectively in different populations including healthy subjects, cryptogenic stroke, transient ischemia attack, and migraine patients. In comparing to the TTD with MCA approach, TOD with CS monitoring could detect comparable rate of RLS, but more high grades of RLS.
Related Concept Videos
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Doppler Effect - I
Doppler Effect - II
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...

