Evaluation of respiratory motion-corrected cone-beam CT at end expiration in abdominal radiotherapy sites: a
Russell E Kincaid1, Agung E Hertanto1, Yu-Chi Hu1
1a Department of Medical Physics , Memorial Sloan Kettering Cancer Center , New York , NY , USA.
Background:
Cone beam computed tomography (CBCT) for radiotherapy image guidance suffers from respiratory motion artifacts. This limits soft tissue visualization and localization accuracy, particularly in abdominal sites. We report on a prospective study of respiratory motion-corrected (RMC)-CBCT to evaluate its efficacy in localizing abdominal organs and improving soft tissue visibility at end expiration.
Material And Methods:
In an IRB approved study, 11 patients with gastroesophageal junction (GEJ) cancer and five with pancreatic cancer underwent a respiration-correlated CT (4DCT), a respiration-gated CBCT (G-CBCT) near end expiration and a one-minute free-breathing CBCT scan on a single treatment day. Respiration was recorded with an external monitor. An RMC-CBCT and an uncorrected CBCT (NC-CBCT) were computed from the free-breathing scan, based on a respiratory model of deformations derived from the 4DCT. Localization discrepancy was computed as the 3D displacement of the GEJ region (GEJ patients), or gross tumor volume (GTV) and kidneys (pancreas patients) in the NC-CBCT and RMC-CBCT relative to their positions in the G-CBCT. Similarity of soft-tissue features was measured using a normalized cross correlation (NCC) function.
Results:
Localization discrepancy from the end-expiration G-CBCT was reduced for RMC-CBCT compared to NC-CBCT in eight of eleven GEJ cases (mean ± standard deviation, respectively, 0.21 ± 0.11 and 0.43 ± 0.28 cm), in all five pancreatic GTVs (0.26 ± 0.21 and 0.42 ± 0.29 cm) and all ten kidneys (0.19 ± 0.13 and 0.51 ± 0.25 cm). Soft-tissue feature similarity around GEJ was higher with RMC-CBCT in nine of eleven cases (NCC =0.48 ± 0.20 and 0.43 ± 0.21), and eight of ten kidneys (0.44 ± 0.16 and 0.40 ± 0.17).
Conclusions:
In a prospective study of motion-corrected CBCT in GEJ and pancreas, RMC-CBCT yielded improved organ visibility and localization accuracy for gated treatment at end expiration in the majority of cases.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Mechanism of Breathing II: Expiration
Expiration, or exhaling, is a complex physiological process that begins as the inspiratory muscles begin to relax. This relaxation triggers a series of events that epitomize the efficiency of the respiratory system.
Mechanism of Expiration:
Conserved Binding Sites
Binding sites are often located in large pockets, and if their location on a protein’s surface is unknown, it can be predicted using various approaches. The energetic method computationally...
Distance Corrections
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT