Feasibility assessment of yttrium-90 liver radioembolization imaging using amplitude-based gated PET/CT
Dustin R Osborne1, Shelley N Acuff, Melissa L Neveu
1Department of Radiology, University of Tennessee Graduate School of Medicine, University of Tennessee Medical Center, Knoxville, Tennessee, USA.
Purpose:
The usage of PET/computed tomography (CT) to monitor hepatocellular carcinoma patients following yttrium-90 (Y) radioembolization has increased. Respiratory motion causes liver movement, which can be corrected using gating techniques at the expense of added noise. This work examines the use of amplitude-based gating on Y-PET/CT and its potential impact on diagnostic integrity.
Patients And Methods:
Patients were imaged using PET/CT following Y radioembolization. A respiratory band was used to collect respiratory cycle data. Patient data were processed as both standard and motion-corrected images. Regions of interest were drawn and compared using three methods. Activity concentrations were calculated and converted into dose estimates using previously determined and published scaling factors. Diagnostic assessments were performed using a binary scale created from published Y-PET/CT image interpretation guidelines.
Results:
Estimates of radiation dose were increased (P<0.05) when using amplitude-gating methods with Y PET/CT imaging. Motion-corrected images show increased noise, but the diagnostic determination of success, using the Kao criteria, did not change between static and motion-corrected data.
Conclusion:
Amplitude-gated PET/CT following Y radioembolization is feasible and may improve Y dose estimates while maintaining diagnostic assessment integrity.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Underflow Gates
Ligand-Gated Ion Channel Receptor: Gating Mechanism