Carotid Doppler sonography: additional tool to assess hemodynamic improvement after transcatheter aortic valve
Valeria Cammalleri1, Francesco Romeo, Massimo Marchei
1Department of Cardiovascular Disease, Tor Vergata University of Rome, Rome, Italy.
Purpose:
The aim of our study was to assess the arterial cerebral blood flow variations in patients with aortic valve stenosis, immediately after the transcatheter aortic valve implantation (TAVI).
Methods:
The study population includes 62 consecutive patients who underwent TAVI for aortic valve stenosis (95%) and sugical bioprosthesis degeneration (5%). Carotid Doppler examination was performed recording blood flow, systolic peak velocity, time average mean velocity and mean acceleration time at baseline, after balloon aortic valvuloplasty, and within 10 min after the device release.
Results:
A significant improvement of blood flow was recorded at the end of the procedure (from 315.05 ± 141.72 to 538.67 ± 277.46 ml/min; P < 0.00001). The systolic peak velocity and the time average mean velocity increased from 52.27 ± 14.29 to 78.89 ± 20.48 cm/s (P < 0.00001) and from 12.24 ± 4.74 to 21.21 ± 9 cm/s (P < 0.00001), respectively. Consensually, the mean acceleration time decreased from 0.22 ± 0.02 to 0.03 ± 0.02 s (P < 0.00001) after the procedure.
Conclusion:
Monitoring of Doppler measurements may be a useful and noninvasive method to assess acutely the improvement of hemodynamic flow after TAVI, specifically for the cerebral district.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Mitral Valve Prolapse II: Assessment and Management
Doppler Effect - I
Doppler Effect - II
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...