A microfluidic distributor combining minimal volume, minimal dispersion and minimal sensitivity to clogging
Sander Jespers1, Sander Deridder1, Gert Desmet1
1Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussels, Belgium.
Journal of Chromatography. A
|January 21, 2018
Summary
A novel mixed-mode (MM) microfluidic flow distributor offers improved performance, especially when clogging occurs. It balances low dispersion without clogging against effective management of local clogging events.
Area of Science:
- Microfluidics
- Fluid Dynamics
- Chemical Engineering
Background:
- Microfluidic flow distributors are crucial for applications requiring precise fluid handling.
- Clogging is a significant challenge in microfluidic systems, impacting performance and reliability.
- Existing distributors like bifurcating (BF) and radially interconnected (RI) have limitations.
Purpose of the Study:
- To introduce and evaluate a new mixed-mode (MM) microfluidic flow distributor.
- To assess the performance of the MM-distributor under varying degrees of clogging.
- To compare the MM-distributor against established BF and RI distributor designs.
Main Methods:
- Computational Fluid Dynamics (CFD) simulations were employed to analyze flow characteristics.
- Performance was evaluated in both clear and intentionally clogged microfluidic systems.
- Dispersion and dependency on distributor width were key performance metrics.
Main Results:
- In the absence of clogging, the MM-distributor exhibited slightly higher dispersion than BF but significantly less than RI.
- MM-distributor dispersion showed a power-2 dependency on width, similar to BF, unlike RI's disadvantageous power-4 dependency.
- With increasing clogging, the MM-distributor rapidly outperformed the BF-distributor due to its fluid contact zones.
Conclusions:
- The MM-distributor presents a superior compromise for microfluidic applications where clogging is a potential issue.
- Its design effectively mitigates the impact of local clogging while maintaining low dispersion.
- The MM-distributor is recommended for wider microfluidic systems where clogging cannot be ruled out.
Related Concept Videos
Types of Errors: Detection and Minimization
11.5K
Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
11.5K
Distribution and Dispersion
25.5K
To understand intra-specific interactions in populations, scientists measure the spatial arrangement of species individuals. This geographic arrangement is known as the species distribution or dispersion. Highly territorial species exhibit a uniform distribution pattern, in which individuals are spaced at relatively equal distances from one another. Species that are highly tied to particular resources, such as food or shelter, tend to concentrate around those resources, and thus exhibit a...
25.5K
Le Chatelier's Principle: Changing Volume (Pressure)
40.8K
For gas-phase equilibria, changes in the concentrations of reactants and products can occur with altered volume and pressure. The partial pressure, P, of an ideal gas is proportional to its molar concentration, M.
40.8K
Constant Volume Calorimetry
30.9K
Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.9K
Volume of Distribution
1.4K
The apparent volume of distribution (Vd) is a crucial pharmacokinetic parameter representing the hypothetical body fluid volume into which a drug disperses. It is calculated based on the total amount of drug in the body (estimated from the administered dose and bioavailability) divided by the plasma drug concentration. The total amount of drug in the body does not directly refer to the dose given but is derived by accounting for absorption, distribution, metabolism, and excretion processes.
1.4K
Problem Solving: Volume
91
The volume of a fuel tank mounted on the wing of a jet aircraft can be modeled using the concept of solids of revolution. In this case, the tank is formed by rotating a two-dimensional region, defined by a mathematical function, about the x-axis. The region extends along the axis from zero to two meters, and the resulting three-dimensional shape is symmetric about the axis of rotation. Because the boundary curve lies directly against the axis, the disk method is an appropriate technique for...
91