Related Experiment Video
Updated: Feb 15, 2026

Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Differences in lung injury after IMRT or proton therapy assessed by 18FDG PET imaging
Nadya Shusharina1, Zhongxing Liao2, Radhe Mohan2
1Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States.
Background And Purpose:
To compare lung injury among non-small cell lung cancer (NSCLC) patients treated with IMRT or proton therapy as revealed by 18F-FDG post-treatment uptake and to determine factors predictive for clinically symptomatic radiation pneumonitis.
Material And Methods:
For 83 patients treated with IMRT or proton therapy, planning CT and follow up 18F-FDG PET-CT were analyzed. Post-treatment PET-CT was aligned with planning CT to establish a voxel-to-voxel correspondence between PET and planning dose images. 18F-FDG uptake as a function of radiation dose to normal lung was obtained for each patient. PET image-derived parameters as well as demographic, clinical, treatment and dosimetric patient characteristics were correlated with clinical symptoms of pneumonitis.
Results:
The dose distributions for the two modalities were significantly different; V5 was higher for IMRT, whereas V60 was higher for protons. The mean lung dose (MLD) was similar for the two modalities. The slope of linear 18F-FDG-uptake - dose response did not differ significantly between the two modalities. The MLD, slope, and 95th percentile of SUV were identified as three major factors associated with radiation pneumonitis.
Conclusions:
Despite significantly different dose distributions for IMRT and for protons, the slope of the SUV-dose linear regression line previously shown to be associated with RP did not differ between IMRT and protons. Patients who developed radiation pneumonitis had statistically significantly higher MLD and higher slope regardless of treatment modality.
Related Concept Videos
Lung Capacity
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)