Related Experiment Video
Updated: Feb 15, 2026

Automated Delivery of Microfabricated Targets for Intense Laser Irradiation Experiments
Published on: January 28, 2021
An in silico comparative dosimetric study of postmastectomy locoregional irradiation using intensity-modulated vs
Pooja Khullar1, Charu Garg1, Sujit Nath Sinha1
1Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India.
Abstract:
An in silico dosimetric evaluation of intensity-modulated radiation therapy (IMRT) vs 3-dimensional conventional radiation therapy (3D-CRT) treatment plans in postmastectomy radiation therapy (PMRT) to the chest wall and regional lymphatics was conducted. Twenty-five consecutive patients with breast cancer referred for locoregional PMRT, stages T2-4 with N1-3, were planned to receive 50 Gy in 25 fractions with IMRT. Additionally, a 3D-CRT plan was generated using identical contours for the clinical target volumes (CTV), planning target volumes (PTV), and organs at risk (OAR). Treatment plans were assessed using dose-volume histogram (DVH) parameters of D98, D95, D50, D2, and homogeneity index for individual CTVs and PTVs. OARs evaluated were ipsilateral and contralateral lungs, heart, spinal cord, and opposite breast. Most DVH parameters pertaining to CTVs and PTVs significantly favored IMRT. V20 for ipsilateral and contralateral lungs, D33 of heart and maximum dose to spinal cord favored IMRT (all p < 0.001). The mean dose to the opposite breast was significantly lesser with 3D-CRT (5.8 ± 1.8 Gy vs 2.0 ± 1.0 Gy, p < 0.001). Thus, except for the mean dose to the opposite breast, the compliance to DVH constraints applied to PTV and OARs were significantly better with IMRT. At a median follow-up of 76 months (7-91), none had locoregional failure or pulmonary or cardiac morbidity. For PMRT, requiring comprehensive irradiation to both chest wall and regional lymphatics, IMRT offers superior dosimetric advantages over 3D-CRT. This was also corroborated by long-term outcomes in these patients treated with IMRT.
Related Concept Videos
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Sound Intensity
Enolate Mechanism Conventions
Comparative Excretory Systems
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...

