Related Experiment Video
Updated: Feb 15, 2026

Use of a Video Scoring Anchor for Rapid Serial Assessment of Social Communication in Toddlers
Published on: March 14, 2018
Concurrent criterion validity of a novel portable motion analysis system for assessing the landing error scoring
Gali Dar1,2, Alon Yehiel2, Maya Cale' Benzoor1,2
1a Faculty of Social Welfare & Health Studies, Department of Physical Therapy , University of Haifa , Haifa , Israel.
Abstract:
The landing error scoring system (LESS) assesses the quality of a landing after a jump. The quality of the jump is usually evaluated using a three-dimensional (3-D) motion analysis system or a two-dimensional (2-D) video analysis visually rated by a clinician. However, both methods have disadvantages. The aim of this study was to examine the concurrent validity of a novel portable motion analysis system ('PhysiMax System') in assessing the LESS score by comparing it to video analysis. The study population included 48 healthy participants (28.45 ± 5.61 years), each performing the LESS test while two video cameras and the 'PhysiMax' simultaneously recorded the jump. The 'Physimax' system automatically evaluated the LESS. Subsequently, the examiners scored the test by viewing the video recordings, blinded to the 'PhysiMax' results. The mean LESS score, using the video recordings and the 'PhysiMax' was 4.77 (±2.29) and 5.15 (±2.58), respectively, (ICC = 0.80, 95% confidence intervals 0.65-0.87), mean absolute differences 1.13 (95% confidence intervals; 0.79-1.46). The results indicate a high consensus between the methods of measurement. The 'Physimax' system's main advantages are portability, objective evaluation and immediate availability of results. The system can be used by athletic trainers and physiotherapists in the clinic and in the field for jumping assessment.
More Related Videos
Related Concept Videos
The Colonization of Land
Reliability and Validity
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Relative Motion Analysis - Velocity