Related Experiment Video
Updated: Feb 15, 2026

A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
An approach to testing undiluted e-cigarette aerosol in vitro using 3D reconstituted human airway epithelium
Abstract:
The data presented here show that to provide an estimate of the relative cytotoxicity and therefore potency of e-cigarettes, undiluted aerosol techniques can be used. With the emergence of electronic nicotine delivery systems, fit-for-purpose in vitro screening methods are required. Reconstituted 3D human airway epithelium, was exposed to undiluted aerosols at the air-liquid interface, using a Vitrocell VC 10. TEER, cilia beat frequency and cytotoxic responses were assessed. Using two smoking regimes (ISO and HCI) a 3R4F reference cigarette, produced IC50s of 5.2 and 2.1 min, 1458 ng/mL and 1640 ng/mL nicotine respectively. Using an open tank e-cigarette device, a full cytotoxicity dose-response curve was obtained giving an IC50 of 30 min with corresponding nicotine of 10,957 ng/mL, 6-14 times less cytotoxic than cigarette smoke. A commonly used e-liquid flavourant cinnamaldehyde and known skin sensitizer was added to the standard e-liquid formulation and used as an aerosolised positive control, at 0.1, 0.025, 0.01 and 0%, demonstrating a full dose response. The delivery of undiluted aerosols in vitro has resulted in increased method sensitivity, throughput and quantitative e-cigarette comparisons. A positive control aerosol generated from a 'safe' e-liquid benchmark can inform risk assessments on supportable levels of flavour ingredients.
More Related Videos
09:07Author Spotlight: Development and Characterization of an In Vitro Model to Study Chronic Cigarette Smoke Exposure and Its Impact on Airway Epithelial Cells in COPD Research
Published on: July 12, 2024
08:25Advanced 3D Liver Models for In vitro Genotoxicity Testing Following Long-Term Nanomaterial Exposure
Published on: June 5, 2020
Related Concept Videos
In Vitro Drug Dissolution: Compendial Testing Models I
In Vitro Drug Dissolution: Compendial Testing Models II
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
In Vitro Drug Release Testing: Overview, Development and Validation
Classification of Epithelial Tissues: Simple Epithelium
Because of the thinness of the cells, simple squamous epithelium is present where the rapid passage of chemical compounds is observed. For example, the endothelium that lines the capillaries and vessels...