Related Experiment Video
Updated: Feb 15, 2026

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
A functionally personalized boundary condition model to improve estimates of fractional flow reserve with CT (CT-FFR)
Moti Freiman1, Hannes Nickisch2, Holger Schmitt2
1Global Advanced Technology, CT BU, Advanced Technologies Center, Philips Healthcare, Building No. 34, P.O. Box 325, Haifa, 3100202, Israel.
Purpose:
The purpose of this study is to develop and evaluate a functionally personalized boundary condition (BC) model for estimating the fractional flow reserve (FFR) from coronary computed tomography angiography (CCTA) using flow simulation (CT-FFR).
Materials And Methods:
The CCTA data of 90 subjects with subsequent invasive FFR in 123 lesions within 21 days (range: 0-83) were retrospectively collected. We developed a functionally personalized BC model accounting specifically for the coronary microvascular resistance dependency on the coronary outlets pressure suggested by several physiological studies. We used the proposed model to estimate the hemodynamic significance of coronary lesions with an open-loop physics-based flow simulation. We generated three-dimensional (3D) coronary tree geometries using automatic software and corrected manually where required. We evaluated the improvement in CT-FFR estimates achieved using a functionally personalized BC model over anatomically personalized BC model using k-fold cross-validation.
Results:
The functionally personalized BC model slightly improved CT-FFR specificity in determining hemodynamic significance of lesions with intermediate diameter stenosis (30%-70%, N = 72), compared to the anatomically personalized model lesions with invasive FFR measurements as the reference (sensitivity/specificity: 0.882/0.79 vs 0.882/0.763). For the entire set of 123 coronary lesions, the functionally personalized BC model improved only the area under the curve (AUC) but not the sensitivity/specificity in determining the hemodynamic significance of lesions, compared to the anatomically personalized model (AUC: 0.884 vs 0.875, sensitivity/specificity: 0.848/0.805).
Conclusion:
The functionally personalized BC model has the potential to improve the quality of CT-FFR estimates compared to an anatomically personalized BC model.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
04:37Improved Home Blood Pressure Control by CT-guided Ozone-mediated Renal Denervation for Patients with Resistant Hypertension
Published on: June 6, 2025
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Electrostatic Boundary Conditions
The surface integral of an electric field is given by Gauss's law in integral form and is related to...
Magnetostatic Boundary Conditions
Imaging Studies for Cardiovascular System V: CT
Boundary Conditions for Current Density