Related Experiment Video
Updated: Feb 15, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Effect of Blocking Screws on Union of Infraisthmal Femur Fractures Stabilized With a Retrograde Intramedullary Nail
Bryan Van Dyke1, Ryan Colley1, Christina Ottomeyer1
1Ohio Health, Department of Orthopedic Surgery, Columbus, OH.
Objective:
To investigate the effect of blocking screws (BS) on the union rate and stability of infraisthmal femur fractures treated with retrograde intramedullary nail (RIMN) insertion.
Design:
Retrospective cohort study.
Setting:
A single level 1 trauma center.
Patients/Participants:
All patients with an infraisthmal femur fracture treated with a RIMN from 2005 to 2012 were included.
Intervention:
All fractures were treated with a RIMN. BS were used at the discretion of the treating surgeon.
Main Outcome Measurements:
(1) Radiographic time to union, (2) initial postoperative sagittal and coronal angulation, and (3) final sagittal and coronal angulation.
Results:
Neither the average time to union (BS 21.1 weeks vs. 21.8 weeks), nor union rates (BS 61% vs. 77%) were statistically different between BS and non-BS constructs. No significant alignment differences existed whether BS were used or not.
Conclusions:
In this study, we were not able to verify our hypothesis. In fact, we did not find any significant advantages when BS were added to a RIMN construct for distal femur fractures with respect to union time, union rate, or improvements in alignment. Additional studies are needed to determine the actual benefit of BS in the treatment of infraisthmal femoral shaft fractures treated with retrograde intramedullary nailing.
Level Of Evidence:
Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Nuclear Stability
To hold positively charged protons together...
RNA Stability

