Real-Time Closed Loop Diastolic Interval Control Prevents Cardiac Alternans in Isolated Whole Rabbit Hearts
Kanchan Kulkarni1, Steven W Lee1, Ryan Kluck1
1Department of Biomedical Engineering, University of Minnesota, 6-128 Nils Hasselmo Hall, 312 Church St. SE, Minneapolis, MN, 55455, USA.
Abstract:
Cardiac alternans, a beat-to-beat alternation in action potential duration (APD), can lead to fatal arrhythmias. During periodic pacing, changes in diastolic interval (DI) depend on subsequent changes in APD, thus enhancing cardiac instabilities through a 'feedback' mechanism. Recently, an anti-arrhythmic Constant DI pacing protocol was proposed and shown to be effective in suppressing alternans in 0D and 1D in silico studies. However, previous experimental validation of Constant DI pacing in the heart has been unsuccessful due to the spatio-temporal complexity of 2D cardiac tissue and the technical challenges in its real-time implementation. Here, we developed a novel closed loop system to detect T-waves from real-time ECG data, enabling successful implementation of Constant DI pacing protocol, and performed high-resolution optical mapping experiments on isolated whole rabbit hearts to validate its anti-arrhythmic effects. The results were compared with: (1) Periodic pacing (feedback inherent) and (2) pacing with heart rate variability (HRV) (feedback modulation) introduced by using either Gaussian or Physiological patterns. We observed that Constant DI pacing significantly suppressed alternans in the heart, while maintaining APD spatial dispersion and flattening the slope of the APD restitution curve, compared to traditional Periodic pacing. In addition, introduction of HRV in Periodic pacing failed to prevent cardiac alternans, and was arrhythmogenic.
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Critical Numbers and the Closed Interval Method
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Catheterization II: Right Heart Catheterization
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.