Related Experiment Video
Updated: Feb 15, 2026

Organ Ischemia-Reperfusion Injury by Simulating Hemodynamic Changes in Rat Liver Transplant Model
Published on: March 6, 2021
Modelling the immunosuppressive effect of liver SBRT by simulating the dose to circulating lymphocytes: an in-silico
L Basler1, N Andratschke2, S Ehrbar2
1University Hospital Zurich, Department of Radiation Oncology, University of Zurich, Rämistrasse 100, CH 8091, Zürich, Switzerland. Lucas.Basler@usz.ch.
Background:
Tumor immune-evasion and associated failure of immunotherapy can potentially be overcome by radiotherapy, which however also has detrimental effects on tumor-infiltrating and circulating lymphocytes (CL). We therefore established a model to simulate the radiation-dose delivered to CL.
Methods:
A MATLAB-model was established to quantify the CL-dose during SBRT of liver metastases by considering the factors: hepatic blood-flow, -velocity and transition-time of individual hepatic segments, as well as probability-based recirculation. The effects of intra-hepatic tumor-location and size, fractionation and treatment planning parameters (VMAT, 3DCRT, photon-energy, dose-rate and beam-on-time) were analyzed. A threshold dose ≥0.5Gy was considered inactivating CL and CL0.5 (%) is the proportion of inactivated CL.
Results:
Mean liver dose was mostly influenced by treatment-modality, whereas CL0.5 was mostly influenced by beam-on-time. 3DCRT and VMAT (10MV-FFF) resulted in lowest CL0.5 values of 16 and 19%. Metastasis location influenced CL0.5, with a mean of 19% for both apical and basal and 31% for the central location. PTV-volume significantly increased CL0.5 from 27 to 67% (10MV-FFF) and from 31 to 98% (6MV-FFF) for PTV-volumes ranging from 14cm3 to 268cm3.
Conclusion:
A simulation-model was established, quantifying the strong effects of treatment-technique, tumor-location and tumor-volume on dose to CL with potential implications for immune-optimized treatment-planning in the future.
Related Concept Videos
Bioavailability Study Design: Single Versus Multiple Dose Studies
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses