Diagnostic accuracy of dual-energy computed tomography in bone marrow edema with vertebral compression fractures: A
Pei Yang1, Guangyao Wu1, Xiaodan Chang1
1Department of Radiology, Affiliated Zhongshan Hospital of Dalian University, No.6 Jiefang Street, Dalian 116001, Liaoning Province, China.
Purpose:
This meta-analysis aimed to evaluate the diagnostic performance of dual-energy computed tomography (DECT) for the bone marrow edema (BME) in patients with vertebral compression fractures.
Methods:
The PubMed, EMBASE, and the Cochrane Library database were searched up to July 2017 for relevant original studies. Data were extracted to calculate the pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive and negative likelihood ratios (PLR and NLR), and areas under summary receiver operating characteristic (SROC) curves for analysis.
Results:
A total of seven studies including 510 vertebras were available for the meta-analysis. Overall pooled sensitivity and specificity of DECT for detecting BME were 0.82 (95%CI: 0.76-0.86) and 0.98 (95%CI: 0.97-0.99), respectively. The PLR was 29.74 (95%CI: 15.62-56.61), the NLR was 0.19 (95%CI: 0.11-0.33), and DOR was 201.96 (95%CI: 99.98-407.93). The SROC value was 0.978. In addition, a subgroup analysis was conducted according to the mean time interval between the DECT and MRI. In 5 studies with more than 2 days interval, the pooled sensitivity and specificity of DECT were 0.89 (95%CI: 0.84-0.93) and 0.98 (95%CI: 0.95-0.99), respectively. The AUC value was 0.979.
Conclusions:
Current evidence of our meta-analysis indicates that DECT has a high diagnostic accuracy in BME of vertebral compression fractures. In addition, DECT may have a less sensitive in BME of hyper-acute period.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bone Marrow Sampling and Transplants
The transplant begins with high doses of chemotherapy and radiation treatment, which aim to destroy...
Imaging Studies III: Computed Tomography
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision