Prosthetic liner wear in total hip replacement: a longitudinal 13-year study with computed tomography
Lars Weidenhielm1, Henrik Olivecrona2, Gerald Q Maguire3
1Department of Molecular Medicine and Surgery, Karolinska Institute, Stockholm, Sweden. lars.weidenhielm@sll.se.
Serial computed tomography (CT) scans enabled limited hip replacement revision surgery by monitoring femoral head penetration and liner wear over 13 years. This approach successfully avoided total prosthesis replacement and identified wear progression.
Area of Science:
- Orthopedic surgery
- Medical imaging
- Biomedical engineering
Background:
- Total hip replacement (THR) is a common procedure for hip osteoarthritis.
- Long-term monitoring of THR components is crucial for detecting wear and loosening.
- Osteolysis is a significant complication following hip arthroplasty.
Observation:
- A 45-year-old woman underwent THR in 1992.
- Six serial computed tomography (CT) examinations were performed over 13 years.
- Femoral head penetration into the cup increased from 2.6 mm in 2004 to 5.0 mm in 2017.
Findings:
- Serial CT imaging guided revision surgery to liner replacement only, avoiding full prosthesis removal.
- CT data ruled out osteolysis, which was confirmed during surgery.
- The extracted liner exhibited 5.5 mm of wear at its thinnest point.
- CT revealed a change in liner wear direction from cranial to dorsal.
Implications:
- Modern CT techniques can detect early signs of hip prosthesis wear and complications.
- Non-invasive CT monitoring allows for timely, less invasive revision procedures.
- Accurate assessment of wear progression and direction can optimize implant management and patient outcomes.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Longitudinal Studies
Longitudinal Research
Carbon-13 (¹³C) NMR: Overview
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET