Combining Holographic Optical Tweezers with Upconversion Luminescence Encoding: Imaging-Based Stable Suspension Array
Cheng-Yu Li1, Di Cao1, Chu-Bo Qi1,2
1Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University , Wuhan 430072, People's Republic of China.
Abstract:
Establishment of a stable analytical methodology with high-quality results is an urgent need for screening cancer biomarkers in early diagnosis of cancer. In this study, we incorporate holographic optical tweezers with upconversion luminescence encoding to design an imageable suspension array and apply it to conduct the detection of two liver cancer related biomarkers, carcinoembryonic antigen and alpha fetal protein. This bead-based assay is actualized by forming a bead array with holographic optical tweezers and synchronously exciting the upconversion luminescence of corresponding trapped complex beads fabricated with a simple one-step sandwich immunological recognition. Owing to the fact that these flowing beads are stably trapped in the focal plane of the objective lens which tightly converges the array of the laser beams by splitting a 980 nm beam using a diffraction optical element, a fairly stable excitation condition is achieved to provide reliable assay results. By further taking advantage of the eminent encoding capability of upconversion nanoparticles and the extremely low background signals of anti-Stokes luminescence, the two targets are well-identified and simultaneously detected with quite sound sensitivity and specificity. Moreover, the potential on-demand clinical application is presented by employing this approach to respond the targets toward complex matrices such as serum and tissue samples, offering a new alternative for cancer diagnosis technology.
Related Concept Videos
Encoding
Automatic processing involves the encoding of details like time, space, frequency, and the meaning of words, usually done without conscious...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Colloids and Suspensions
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Combining Functions