Related Experiment Video
Updated: Feb 15, 2026

Multimodal Analysis of Microplastics in Drinking Water using a Silicon Nanomembrane Analysis Pipeline
Published on: June 13, 2025
Results for Water-drinking Test, before and after Laser Iridotomy, in Primary Angle-closure Suspects
M Reza Razeghinejad1,2, Parisa Karampour2, Masoumeh Beigom Masoumpour
1Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska.
Significance:
Intraocular pressure and ocular biometric changes were similar before and after laser iridotomy in response to the water-drinking test in a cohort of patients at risk of angle closure. The water-drinking test does not seem to be a good provocative test to determine which eyes would benefit from a laser iridotomy. Our data call into question the preoperative predictive value of this test.
Purpose:
The aim of this study was to evaluate the effect of water-drinking test on intraocular pressure and ocular biometric parameters, before and after laser peripheral iridotomy, in patients with an occludable angle.
Methods:
Twenty-seven patients, who met the inclusion criteria and had at least 180 degrees of iridotrabecular apposition, underwent a complete eye examination followed by the measurement of ocular biometric (using LenStar LS-900; Haag-Streit AG, Koeniz, Switzerland) and anterior chamber parameters (using Pentacam HR; Oculus Optikgerate GmbH, Wetzlar, Germany). All the measurements were repeated 30 minutes after the water-drinking test. Two weeks after laser peripheral iridotomy, all the measurements were repeated both before and after the water-drinking test.
Results:
The mean ± SD of the age of the participants was 57 ± 9 years, and 23 (85.2%) were male. Intraocular pressure increased after the water-drinking test in both pre-laser peripheral iridotomy (17.0 vs. 19.3 mmHg, P < .001) and post-laser peripheral iridotomy (15.6 vs. 18.6 mmHg, P < .001) conditions. The thickness values of central cornea increased slightly after the water-drinking test in pre-laser peripheral iridotomy (535 vs. 538 μm, P = .001) compared with post-laser peripheral iridotomy (532 vs. 536 μm, P = .003). The water-drinking test had no significant effect on other biometric or anterior chamber parameters, before or after laser peripheral iridotomy.
Conclusions:
The water-drinking test increased intraocular pressure, both before and after laser peripheral iridotomy. Laser peripheral iridotomy had no significant effect on the amount of intraocular pressure change after the water-drinking test. The water-drinking test has no effect on other biometric or anterior chamber parameters.
More Related Videos
07:31Murine Drinking Models in the Development of Pharmacotherapies for Alcoholism: Drinking in the Dark and Two-bottle Choice
Published on: January 7, 2019
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
Related Concept Videos
Angle Closure Glaucoma: Treatment
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle of Twist: Problem Solving
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Design Example: Traverse Angle Computations