Human Subcutaneous Adipose Tissue Sampling Using a Mini-Liposuction Technique
Published on: September 27, 2021
A Multicenter, Prospective, Randomized, Contralateral Study of Tissue Liquefaction Liposuction vs Suction-Assisted
Joseph P Hunstad1, Christopher P Godek2, Bruce W Van Natta3
1plastic surgeons in private practice in Huntersville, NC.
Background:
Tissue liquefaction liposuction (TLL) deploys a novel energy source utilizing a stream of warmed, low-pressurized, and pulsed saline to extract fat tissue.
Objectives:
Compare TLL to suction-assisted liposuction (SAL) to determine which device is more efficient for surgeons and provides better recovery for patients.
Methods:
Thirty-one adult female patients were followed prospectively in a contralateral study design comparing differences in bruising, swelling, tenderness, and incision appearance ratings between TLL and SAL procedures. Surgical efficiency and appearance of the lipoaspirate were also compared.
Results:
All 31 patients successfully completed the study. For TLL and SAL procedures, the average volumes of infusion (1.242 vs 1.276 L) and aspirated supernatant fat (704 vs 649 mL) were statistically similar. TLL median fat extraction rate was faster than SAL (35.6 vs 25 mL/min; P < 0.0001), and stroke rate was reduced in TLL vs SAL procedures (48 vs 120 strokes/min; P < 0.0001), and both were statistically significant. The mean total scores for bruising, swelling, treatment site tenderness, and incision appearance were lower, indicating improved patient recovery on the TLL side.
Conclusions:
TLL and SAL techniques produced comparable volume of fat aspirate. TLL demonstrated a 42% faster fat extraction rate and a 68% reduction in arm movements needed to complete the procedure compared to SAL, both of these differences are statistically significant. The TLL side was noted to have reduced bruising and swelling and improved incision site appearance with less tenderness compared to the SAL side.
More Related Videos
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Tracheostomy Suctioning II: Procedure
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...