Related Experiment Video
Updated: Feb 15, 2026

Sleeve Gastrectomy in Mice using Surgical Clips
Published on: November 14, 2020
Endoscopic stent placement for treatment of sleeve gastrectomy leak: a single institution experience with fully
Sara E Martin Del Campo1, Dean J Mikami2, Bradley J Needleman1
1Center for Minimally Invasive Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio.
Background:
Laparoscopic sleeve gastrectomy (SG) has risen in prevalence as a standalone surgical option for treating obesity over the last 15 years. One of the most worrisome complications is development of a leak at the gastrectomy staple line.
Objective:
The objective of this report is to describe our single-institution experience in managing SG staple-line leaks with fully covered endoscopic stents.
Setting:
Academic medical center, United States.
Methods:
Data for all patients who underwent endoscopic stent placement for an SG leak between 2010 and 2016 at a single academic institution were retrospectively reviewed. Patient medical history, perioperative information, stent placement details, outcomes, and subsequent interventions were recorded.
Results:
Twenty-four patients with SG staple-line leaks treated with fully covered endoscopic stents were identified. Leaks were identified at a median of 31.5 days postoperatively (range, 1-1615 d). The majority of patients underwent other treatment(s) for their leak before stent placement at our institution. Stents remained in place for an average of 28.8 ± 16.8 days. Migration occurred in 22% of all stent placements. Three patients were lost to follow-up, and 14 of the remaining 21 patients (66.7%) healed after stent placement. Five patients (23.8%) ultimately required operative revision with partial gastrectomy and Roux-en-Y esophagojejunostomy for management of persistent leaks.
Conclusion:
Endoscopic management using fully covered stents for staple-line leaks after SG is effective in the majority of patients. However, algorithms are needed for the management of chronic staple-line leaks, which are less likely to heal with stent placement.
Related Concept Videos
What is an Experiment?
Thomson's e/m Experiment
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures II: Colonoscopy
Controls in Experiments

