Related Experiment Video
Updated: Feb 15, 2026

Two-photon Calcium Imaging in Mice Navigating a Virtual Reality Environment
Published on: February 20, 2014
Virtual Computed Tomography Colonography: Evaluation of 2D and Virtual 3D Image Quality of Sub-mSv Examinations
Hannes Seuss1, Rolf Janka1, Matthias Hammon1
1Department of Radiology, University Hospital Erlangen, Friedrich Alexander University, Erlangen-Nuernberg, (FAU), Maximiliansplatz 3, 91054, Germany.
Rationale And Objectives:
To evaluate two- and three-dimensional (2D and 3D) image quality of sub-milliSievert (mSv) computed tomography (CT) colonography utilizing a third-generation dual source CT scanner featuring a tin filter.
Methods:
We retrospectively evaluated 26 consecutive patients who underwent third-generation dual source CT colonography, nine with the standard-dose clinical-scan protocol (SDP) and 17 with a low-dose protocol (LDP) featuring a tin filter. Radiation dose was evaluated by volume computed tomography dose index (CTDIvol), dose length product (DLP), effective dose (E), and size-specific dose estimate. Objective image quality was evaluated utilizing signal-to-noise ratio (SNR) derived from standardized placed regions of interest on the transverse 2D images and the ratio of SNR/CTDIvol (normalized SNR). Two radiologists in consensus assessed subjective image quality of the virtual 3D images.
Results:
There were no significant differences in subjective image quality (P = .661). All examinations were rated "excellent" or "good" for diagnostic confidence. The mean total for DLP/E was 143.4 ± 29.8 mGy/3.00 ± 0.40 mSv in the SDP and therefore significantly higher than in the LDP with 36.9 ± 8.7 mGy/0.75 ± 0.16 mSv (P < .001). The SNR was 8.9 ± 2.1 in the SDP and 4.9 ± 0.8 in the LDP.
Conclusions:
Third-generation dual source CT featuring a tin filter enables consistent sub-mSv colonography without substantially impairing image quality.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
10:14Author Spotlight: Enhancing Neurorehabilitation Through EEG, Motor Imagery, and Virtual Reality
Published on: May 10, 2024
Related Concept Videos
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Principle of Virtual Work: Problem Solving
To apply the principle of virtual work,...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Virtual Work for a System of Connected Rigid Bodies
Next,...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...