The common use of improper control diets in diet-induced metabolic disease research confounds data interpretation:

Michael A Pellizzon1, Matthew R Ricci1

  • 1Research Diets, Inc, 20 Jules Lane, New Brunswick, NJ 08901 USA.

Nutrition & Metabolism
|January 27, 2018
PubMed

Related Concept Videos

Bioequivalence Data: Statistical Interpretation01:16

Bioequivalence Data: Statistical Interpretation

Body:The statistical interpretation of bioequivalence data is a significant aspect of pharmaceutical research. Bioequivalence refers to the absence of any significant difference in the rate and extent to which the active ingredient in pharmaceutical products becomes available at the site of drug action when administered at the same molar dose under similar conditions. This helps determine if different drug products have similar absorption rates, ensuring their interchangeability.Statistical...
226
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
408
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
394
Confounding in Epidemiological Studies01:27

Confounding in Epidemiological Studies

Confounding in statistical epidemiology represents a pivotal challenge, referring to the distortion in the perceived relationship between an exposure and an outcome due to the presence of a third variable, known as a confounder. This variable is associated with both the exposure and the outcome but is not a direct link in their causal chain. Its presence can lead to erroneous interpretations of the exposure's effect, either exaggerating or underestimating the true association. This...
861
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
441
Improper Integrals: Infinite Intervals01:29

Improper Integrals: Infinite Intervals

An integral is classified as improper due to an infinite interval when at least one of its limits of integration extends to positive or negative infinity. In such cases, the region under the curve is unbounded, and standard techniques for evaluating definite integrals are not directly applicable. Instead, the improper integral is defined through a limiting process that allows one to determine whether the accumulated area remains finite despite the infinite domain.Application to Exponential...
118