Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
[High sensitive non-derivative determination of cyclovirobuxin D by high-performance liquid
Zhen Long1, Paul Gamache2, Zhimou Guo3
1Thermo Fisher Scientific Corporation, Beijing 100080, China.
Abstract:
A high-performance liquid chromatography-electrochemical detection (HPLC-ECD) method was developed to determine cyclovirobuxin D (CVB-D) levels in tablets and human blood samples. A column with a positive charge-modified C18 stationary phase, C18HCE, was selected to analyze CVB-D, because it provided a sharper and more symmetric peak for CVB-D than conventional C18 stationary phase. Two types of working electrode materials, glassy carbon (GC) and boron-doped diamond (BDD), were evaluated. BDD was found to provide better sensitivity than GC owing to its lower background current and baseline noise. Utilizing the BDD electrode, C18HCE column, and optimized mobile phase composition, the developed HPLC-ECD method showed a much better sensitivity. The limit of detection and limit of quantification of the HPLC-ECD method for CVB-D were 0.198 and 0.297 μg/L, respectively. It was approximately 12727, 11481, and 2630 times more sensitive than ultraviolet (UV), evaporative light scattering detection, and charged aerosol detection, respectively. The sensitivity of the developed HPLC-ECD method was comparable or even better (16.8 times) than reported mass spectrometry (MS) methods for the determination of CVB-D. Additionally, it offered a much wider linear dynamic range (up to 4 orders of magnitude, 0.297-1891 μg/L) and was much less complicated than MS methods for determination of CVB-D. The developed HPLC-ECD method can be used for determination of CVB-D at both high and low concentrations. Good intra-day (relative standard deviation (RSD) of peak area<5.08%) and inter-day (RSD of peak area<5.57%) reproducibilities of the developed HPLC-ECD method were obtained even for a low mass concentration (59.1 μg/L) sample. After the optimized parameters were acquired, this method was applied to the quantitative analysis of CVB-D in CVB-D tablets and human blood samples. With a slight modification, the current HPLC-ECD method can also be applied to analyze many other basic compounds including basic drugs and environmental pollutants.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Determining Order of Reaction