Related Experiment Video
Updated: Feb 15, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Placement of baclofen pump catheter through a C1-2 puncture: technical note
Zaid Aljuboori1,2, Jacob Archer1,2, Wei Huff1,2
11Section of Pediatric Neurosurgery, Riley Hospital for Children.
Abstract:
Intrathecal baclofen has been suggested as an effective and safe treatment for intractable spasticity and dystonia. Techniques of lumbar and intraventricular catheter placement have been previously described. The purpose of this study was to describe a technique to implant catheters for intrathecal baclofen infusion through C1-2 puncture. Four of 5 consecutively treated patients underwent successful placement of catheters for intrathecal baclofen. There were no instances of infection, CSF leak, or catheter migration seen during a follow-up period of at least 6 months; furthermore, there were no occurrences of vertebral artery or spinal cord injury. All patients had an effective stabilization or reduction of their upper-extremity, lower-extremity, or trunk tone. There were no cases of worsening hypertonia. The authors' preliminary experience with C1-2 puncture for placement of the intrathecal baclofen catheter seems to indicate that this is a safe and efficacious technique. Lessons learned from the failed attempt at C1-2 puncture will be delineated.
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H

