Related Experiment Video
Updated: Feb 15, 2026

Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023
Determination of Organophosphorous Pesticides in Blood Using Microextraction in Packed Sorbent and Gas
C Santos1,2, D Oppolzer1, A Gonçalves1
1Centro de Investigação em Ciências da Saúde (CICS-UBI), Universidade da Beira Interior, Av. Infante D. Henrique, 6201-556 Covilhã, Portugal.
Abstract:
The aim of our work was to develop a method for the determination of six organophosphorous pesticides (Ops) (azynphos-ethyl (AZP), diazinon (DZN), chlorpyrifos (CLP), chlorfenvinfos (CLF), parathion-ethyl (PRT) and quinalphos (QLP)) in whole blood using microextraction by packed sorbent (MEPS) and analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). The optimization of the MEPS procedure was performed using a design of experiments (DOE) approach, assessing different factors that significantly affected the extraction efficiency. Ultimately, the number of sample strokes, wash volume, percentage of 2-propanol in the wash solvent and the number of elution strokes were successfully optimized using a response surface methodology (RSM). The developed and optimized method was fully validated according to international guidelines. Linearity was established from 2.5 to 50 μg/mL for AZP and from 0.5 to 50 μg/mL for the remaining compounds, with coefficients of determination (R2) higher than 0.99 in all cases. The lower limit of quantification were 2.5 μg/mL (AZP) and 0.5 μg/mL (remaining compounds). Recoveries ranged from 61% to 77%. Intra- and inter-day precision and accuracy were considered adequate according to the guidelines. This is the first method employing MEPS as a sample preparation procedure for the analysis of these OPs in whole blood.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...