[Validation of an analytical methodology to determine polychlorinated biphenyls in samples from blood plasma]
Boris Santiago Ávila1, Carolina Ramírez
1Grupo de Salud Ambiental y Laboral, Dirección de Investigación en Salud Pública, Instituto Nacional de Salud, Bogotá D.C, Colombia. bsavilat@unal.edu.co.
Introduction:
Polychlorinated biphenyls are among the five most toxic persistent contaminants for living organisms according to the Agency for Toxic Substances and Disease Registry (ATSDR).
Objective:
To standardize and validate an analytical method to determine and quantify polychlorinated biphenyl indicators in samples from blood plasma by means of gas chromatography-mass spectrometry.
Materials And Methods:
We fortified a plasma pool to do the matrix assays. Additionally, we used the NIST SRM® 1958 reference material for the veracity and intermediate accuracy assays.
Results:
Methodology recovery percentages ranged between 88.4 and 97.5%, and the bias was less than 20%. Detection and quantification limits were 0.04 μg/L and 0.10 μg/L, respectively, for all polychlorinated biphenyl indicators. The linearity represented by the determination coefficient (R2) varied between 0.9866 and 0.9886. Accuracy, expressed as relative standard deviation was less than 20% in all the linear work range (0.5-500 μg/L). Finally, we analyzed 115 samples from Colombian population in various zones of the country and we found 65 positive samples, from which two samples were above HBM-II (7.0 μg/L, 2XΣPCB 138, 153, 180), and two, above HBM-I (3.5 μg/L, 2XΣPCB 138, 153, 180).
Conclusion:
The method we developed is accurate for PCB analysis in blood plasma samples and could be used for biological surveillance of these contaminants in the Colombian population.
Related Concept Videos
Composition of Blood Plasma
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Protein Buffers in Blood Plasma and Cells
Certain amino acids can exist in a zwitterion state at a...
Reliability and Validity
Development of Analytical Methods
Data Validation
Key parameters for method validation include: