Related Experiment Video
Updated: Feb 15, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Clinical Assessment of Micro-residual Tumors during Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma
Kenji Uemoto1,2, Hiroshi Doi3,4, Hiroya Shiomi3
1Miyakojima IGRT Clinic, Osaka, Japan uemoto@osaka-igrt.or.jp.
Background:
This study aimed to assess the need to consider microscopic invasion in terms of treatment planning in stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma and elucidate the appropriate clinical target volume (CTV) margin.
Patients And Methods:
A total of 121 patients (with 146 liver tumors) who underwent SBRT between July 2007 and August 2016 were analyzed, regarding overall survival and local control (LC).
Results:
The 2- and 5-year LC rates were 91.5% and 89.8%, respectively. Planning target volume (PTV) margin <8 mm was associated with poor LC. Of the 77 patients with PTV margin of <8 mm, age <75 years was associated with poor LC, while alpha-fetoprotein (AFP) ≤20 ng/ml was associated with good LC.
Conclusion:
In patients with high AFP levels, there is a possibility of microscopic invasion around the tumor, suggesting that LC may be improved by adding an additional clinical target volume margin to the gross tumor volume.
Related Concept Videos
Biological Effects of Radiation
Residual Plots
When the residual values are plotted against the variable x, it is called a residual...
Residual Stresses
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...

