Experimental circumferential canaloplasty with a new Schlemm canal microcatheter
Mao-Song Xie1, Yong-Zheng Zheng2, Li-Bin Huang1
1Department of Ophthalmology, First Affiliated Hospital of Fujian Medical University, Fuzhou 350005, Fujian Province, China.
Aim:
To present a new, simple, inexpensive Schlemm canal microcatheter for circumferential canaloplasty in a rabbit model.
Methods:
A rabbit glaucoma animal model was established by intravitreal injection of triamcinolone acetonide. Circumferential canaloplasty with a new Schlemm canal microcatheter (patent license number: 201220029850.0) was performed. The Schlemm canal microcatheter was composed of microcatheter wall and lumen. The wall was made of high refractive index plastic optical fiber that could be attached to an illuminant so that the whole lighted microcatheter was visible during circumferential canaloplasty. The lumen could be attached to an injector for injection of viscoelastic during catheterization. Rabbits were divided randomly into the control, model and treatment groups. Intraocular pressure (IOP) was measured with a Tono-pen tonometer pre-operation and 3, 7, 14, 21 and 28d post-operation. Ultrasound biomicroscopy was performed to visualize the Schlemm canal microcatheter in the Schlemm canal and the sclera pool.
Results:
The Schlemm canal microcatheter could be used to perform circumferential canaloplasty in the rabbit glaucoma animal model. IOP was lower in the treatment group than that in the model group 3, 7, 14 and 28d after operation. There were no significant differences in IOP between the control group and treatment group. The differences among the three groups were statistically significant (3d: F=41.985, P<0.001; 7d: F=65.696, P<0.001; 14d: F=114.599, P<0.001; 28d: F=55.006, P<0.001).
Conclusion:
Circumferential canaloplasty is safe and effective in control of experimental glaucoma model in rabbits.
Related Concept Videos
Experimental Determination of Chemical Formula
Experimental RNAi
Experimental Designs
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...
Comparing Experimental Results: Student's t-Test
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs