Related Experiment Video
Updated: Feb 15, 2026

Fragility Assessment of Bovine Cortical Bone Using Scratch Tests
Published on: November 30, 2017
The thermal conductivity of cortical and cancellous bone
1Institute for Surgical Technology and Biomechanics, University of Bern, Switzerland.arne.feldmann@ istb.unibe.ch.
Abstract:
Surgical interventions close to vulnerable structures, such as nerves, require precise handling of surgical instruments and tools. These tools not only pose the risk of mechanical damage to soft tissues, but they also generate heat, which can lead to thermal necrosis of bone or soft tissues. Researchers and engineers are trying to improve those tools through experimentation and simulations. To simulate temperature distributions in anatomical structures, reliable material constants are needed. Therefore, this study aimed at investigating the thermal conductivity of cortical and cancellous bone. Accordingly, a custom-made steady-state experimental setup was designed and validated. 6 bovine and 3 human cortical bone samples, as well as 32 bovine cancellous bone samples, with variable bone volume fraction were tested. The cancellous bone samples were scanned by micro-computed tomography (µCT) and micro-finite element (µFE) voxel models were created to calculate iteratively the thermal conductivity of the bone marrow. The experimental results provided 0.64 ± 0.04 W/mK for bovine cortical bone and 0.68 ± 0.01 W/mK for human cortical bone. A linear dependency of thermal conductivity on bone volume fraction was found for cancellous bone [R-square (R2) = 0.8096, standard error of the estimates (SEE) = 0.0355 W/mK]. The thermal conductivity of the bone marrow was estimated to be 0.42 ± 0.05 W/mK. These results will help to improve thermal finite element simulations of the human skeleton and aid the development of new surgical tools or procedures.
More Related Videos
07:10A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT
Published on: June 12, 2020
09:23Author Spotlight: Advancing Energy Solutions Using Nanocomposites as Processed Thermoelectric Materials
Published on: May 17, 2024
Related Concept Videos
Conduct Disorder
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Resistance and Conductance
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...