Related Experiment Video
Updated: Feb 15, 2026

Soil Lysimeter Excavation for Coupled Hydrological, Geochemical, and Microbiological Investigations
Published on: September 11, 2016
Muddy puddles - the microbiology of puddles located outside tertiary university teaching hospitals
M Furukawa1,2,3, J McCaughan4, J Stirling1
1Northern Ireland Public Health Laboratory, Department of Bacteriology, Belfast City Hospital, Belfast, UK.
Abstract:
In the British Isles, the frequency of rain results in the formation of puddles on footpaths and roads in/around hospitals. No data are available demonstrating the microbiological composition of such puddles and therefore a study was undertaken to examine the microbiology of puddles in the grounds of two tertiary university-teaching hospitals (18 sites) and compared with control puddles from non-hospital rural environments (eight sites), estimating (i) total viable count; (ii) identification of organisms in puddles; (iii) enumeration of Escherichia coli: (iv) detection of Extended Spectrum β-Lactamase producing organisms and (v) direct antimicrobial susceptibility testing. A mean count of 2·3 × 103 CFU per ml and 1·0 × 109 CFU per ml was obtained for hospital and non-hospital puddles respectively. Isolates (n = 77; 54 hospital and 23 non-hospital) were isolated comprising of 23 species among 17 genera (hospital sites), where the majority (10/16; 62·5%) of genera identified were Gram-negative approximately, a fifth (20·6%) were shared by hospital and non-hospital rural samples. Escherichia coli was detected in half of the hospital puddles and under-half (37·5%) of the rural puddles extended spectrum β-lactamase organisms were not detected in any samples examined. Rainwater puddles from the hospital and non-hospital environments contain a diverse range of bacteria, which are capable of causing infections.
Significance And Impact Of The Study:
This study demonstrated the presence of a wide diversity of bacterial taxa associated with rainwater puddles around hospitals, many of which are capable of causing human disease. Of clinical significance is the presence of Pseudomonas aeruginosa isolated from a hospital puddle, particularly for patients with cystic fibrosis. The presence of potentially disease-causing bacteria in puddles in and around hospitals identifies a new potential environmental reservoir of bacteria. Furthermore work is now needed to define their potential of entering or exiting hospital wards by contaminated footwear.
Insights
Rainwater puddles near hospitals harbor diverse bacteria, including potentially harmful species like Pseudomonas aeruginosa. This highlights a new environmental reservoir of disease-causing microbes that warrants further investigation regarding hospital contamination risks.
Area of Science:
- Environmental microbiology
- Hospital-acquired infections
- Public health
Background:
- Rainfall frequently creates puddles on hospital grounds and surrounding areas.
- Limited data exists on the microbiological composition of these puddles.
- Understanding the microbial content is crucial for infection control.
Purpose of the Study:
- To investigate the microbiological composition of rainwater puddles in hospital environments.
- To compare findings with puddles from non-hospital rural sites.
- To assess the potential for these puddles to act as reservoirs for pathogenic bacteria.
Main Methods:
- Collected puddle samples from 18 hospital sites and 8 rural control sites.
- Quantified total viable bacterial counts (CFU/ml).
- Identified bacterial species, enumerated Escherichia coli, and screened for Extended Spectrum β-Lactamase (ESBL) producing organisms.
- Performed direct antimicrobial susceptibility testing.
Main Results:
- Hospital puddles had a mean count of 2.3 x 10^3 CFU/ml, while rural puddles had 1.0 x 10^9 CFU/ml.
- Identified 23 bacterial species from 17 genera in hospital puddles; 62.5% were Gram-negative.
- Escherichia coli was found in 50% of hospital puddles and 37.5% of rural puddles; no ESBL organisms were detected.
- Pseudomonas aeruginosa was isolated from a hospital puddle.
Conclusions:
- Rainwater puddles in and around hospitals contain a diverse range of bacteria, many with the potential to cause human infections.
- The presence of Pseudomonas aeruginosa is of clinical significance, especially for immunocompromised patients.
- These puddles represent a potential environmental reservoir of bacteria, necessitating further research into footwear-mediated transmission into hospital wards.
Related Concept Videos
Hospitals-II
Nurses that work in...
Hospitals-I
Tertiary Healthcare System
Three-Dimensional Microscopy in Microbiology
History of Microbiology
Nomenclature of Secondary and Tertiary Amines

